BTX ECM 630 Скачать руководство пользователя страница 1

ECM 630 

Exponential Decay Wave 

Electroporation System

Quick Start Guide

Unpacking the System

The shipping carton in which your ECM 630 Electroporation System is 

packed has been specifically designed to provide maximum protection 

to the instrument during transportation and normal handling 

conditions. Upon receipt, the carton should be examined for any 

external damage resulting from shipment.
Open the carton and carefully remove the ECM 630 System and 

inspect the unit for any apparent damage. Save the carton and packing 

materials for future transportation and shipping requirements.

Packing Data

Check the packing slip to ensure that all items ordered and listed are 

included in the shipment. Inform BTX immediately if any parts are 

missing or damaged.

Power Source

As received, the instrument is ready for use with either 100–240 V AC, 

50/60 HZ.
The power requirements are 350 watts. In the USA, the power cord has 

a standard three prong plug.

Installation

Once you have determined that the components of the system have 

not sustained any obvious damage in shipment, proceed with the 

installation.
Remove the insulating tab from the battery at the base of the unit.
Place the generator in a location that is a dry, level, sturdy surface free 

from extremes in ambient temperature, dust or chemical exposures. 

Allow the device to equilibrate to room temperature.
Unpack the safety dome, cuvette rack and disposable cuvette 

chambers. Connect the safety dome, or in the case of the ECM 630 

Electroporator system, specialty electrodes or HT plate handler, into 

the connectors at the bottom right-hand side of front panel.
Connect the mains/power cord to into the back panel at the bottom left.
Power up the system by pushing the rocker switch located on the back 

panel at the bottom left. The display will flash the BTX logo. Once the 

software initializes, the Main Menu screen will appear.
You are now ready to begin your work.

Main Menu

User Protocol Review Screen

Protocols with preset parameters for 

common cell and tissue types.  
Cannot be modified by user, however 

Preset protocols may be copied to User 

Protocols for modification.

Protocols may be copied rom Preset 

Protocols or created from scratch by 

the user for later use.

Download full user's manual at: 

www.btxonline.com

BTX ECM 630 Quick Start Guide   •   www.btxonline.com

Voltage,  Resistance, Capacitance, Number of pulses, Pulse Interval, and 

electrode gap may be modified by tapping on the gray icons for each. 

Green Accept icon may be tapped to proceed to Run Protocol screen.