manualshive.com logo in svg
background image

369711

Video KIT

Installation manual

01/13-01 PC

Содержание TI 369711

Страница 1: ...369711 Video KIT Installation manual 01 13 01 PC...

Страница 2: ...2...

Страница 3: ...2 Meaning of the symbols 19 4 2 3 Completing the Quick Configuration 20 4 2 4 Configuration menu 21 5 Badge programming 23 5 1 Manager master badge 23 5 1 1 New manager master badge 23 5 1 2 Deleting...

Страница 4: ...orised people The Video KIT must only be used on BTicino 2 wire digital systems Old system with bell Existing system with 3 wires and just call 230Vac PS BUS TK BUS PI 346830 BUS 2 1 346000 0322 06 IP...

Страница 5: ...2 Basic diagram PS BUS TK BUS PI 346830 BUS 2 1 230Vac 346000 0322 06 IP30 PRI 230V 50 60Hz 260mA BUS 2 1 27V 1 2A PRI ON OFF MOD P N BUS PL S S A T S N P BUS A Door lock pushbutton S S 18 V 4 A impul...

Страница 6: ...sable the door lock release confirmation sound 3 Reset badge programming pushbutton 4 Microphone adjustment 5 Loudspeaker adjustment 6 Green LED door open notification 7 Green LED communication active...

Страница 7: ...key the programming operations 4 Switch ON entrance panel and cycling key 5 Connection key activates deactivates the sound connection 6 Connection LED 7 Loudspeaker 8 Door lock LED 9 Door lock key act...

Страница 8: ...between the Internal Unit and the sound device it is rec ommended to stay 25 35 cm from the front side of the device Remember that the presence of metal and background noise generated by electric ele...

Страница 9: ...lems described above change the height at which the camera is installed normally 160 to 165 cm to a height of 180 cm and face the lens downwards to improve the quality of the views Note in poor lighti...

Страница 10: ...10 4 5 CLAC 1 2 CLAC 4 5 CLAC 3 3 Installation...

Страница 11: ...Video Kit Installation manual 11 8 7 6 9 Press hard 5 10 mm...

Страница 12: ...indoors it must not be exposed to water drops or splashes do not block the ventilation openings it must be used only on SCS BTicino 2 wire systems An improper use of the item can compromise its safet...

Страница 13: ...secure the base in place use wall plugs and screws of suitable sizes Do not directly fasten the base to the flush mounted box To remove the internal unit from the base lower the securing tab A using...

Страница 14: ...0 m 0 28 mm2 140 m 115 m 100 m 30 m BTicino C9881U 5E AWG24 UTP5 145 m 80 m 65 m BTicino 336904 200 m 200 m 200 m 50 m One PTT 278TP 0 28 mm2 200 m 115 m 100 m 30 m OneSYT DigitalTP 5 10 145 m 80 m 65...

Страница 15: ...8 s 10 s Every time the configuration is altered the system must be switched off and back on again waiting for about 1 minute 4 Configuration P do not configure N do not configure T door lock timer re...

Страница 16: ...16 N do not configure P do not configure M mode it defines the main menu page and therefore the functions that can be used 4 2 Internal unit configuration N P M 4 Configuration...

Страница 17: ...mode The main menu page will consist of a set of preset video door entry system and home automation functions that may be selected with M 0 9 The page includes 5 functions plus the Settings which ope...

Страница 18: ...18 M 6 M 7 M 8 M 9 The default configuration is M 0 4 Configuration...

Страница 19: ...onfigured with P 2 Cycle cameras Cyclically activates the cameras in the system starting from the associated Entrance Panel P just one complete cycle is performed Answering machine It can be used to r...

Страница 20: ...nal unit is ready for normal operation The display shows a mask summarising the configuration made Select CONFIRM Select the language required from those offered Press OK to confirm the selection Pres...

Страница 21: ...age is displayed Press OK to confirm Select CONFIGURATION Select QUIT Press OK to quit WARNING AREA RESERVED FOR CONFIGURATION OF THE DEVICE QUIT CONTINUE Select CONTINUE Press OK to confirm WARNING A...

Страница 22: ...AGING Internal unit configured with PAGING YES enables the paging function On selecting OPTIONS access is possible to the following system settings Press OK to confirm Select NO YES Select e g SLAVE S...

Страница 23: ...the badge has been accepted or deleted by means of sound notifications as well as visual indications using the LEDs on the entrance panel The presentation of an unrecognised badge or a programming er...

Страница 24: ...LED to switch on a double confirmation sound will be heard If a system manager badge is already present the new one will replace the old one 2 beeps Manager master If the saving operation fails the re...

Страница 25: ...gramming pushbutton again for 10 seconds When the cancellation is completed the door lock green LED comes on and the device emits 2 beeps 10s 2 beeps Press and hold down the programming pushbutton unt...

Страница 26: ...usy LED will also come on Move the system manager badge close to the reader until the green door lock LED flashes and a confirmation sound is heard 1 beep Manager master Move the resident badge to sav...

Страница 27: ...Video Kit Installation manual 27 If the saving operation fails the red busy LED flashes and the device emits a long beep 1 extended beep...

Страница 28: ...ice in succession When the cancella tion is completed the door lock green LED comes on and the device emits 2 beeps Move the system manager badge close to the reader until the green door lock LED flas...

Страница 29: ...m manager and residents the entrance panel can be reset ON ON OFF OFF RemovetheBUS pressandholddowntheprogram ming pushbutton reconnect the power supply Press and hold down the programming pushbutton...

Страница 30: ...NC NO A PS BUS TK BUS PI 346830 BUS 2 1 230Vac 346000 0322 06 IP30 PRI 230V 50 60Hz 260mA BUS 2 1 27V 1 2A PRI BUS PL S S T S N P 8 A cos 1 24 Vdc 24 Vac 4 A cos 0 7 24 Vac 3 A cos 0 4 24 Vac A Door l...

Страница 31: ...t the corresponding menu icon 1 2 5 6 ON 3 230Vac 346200 PS BUS TK BUS PI 346830 BUS PL S S 346200 0404 06 T S N P BUS 2 1 230Vac 3 4 6 0 0 0 0322 06 IP30 PRI230V 50 60Hz 260mA BUS 2 1 27V 1 2A PRI MO...

Страница 32: ...P J M P 1 A PS BUS TK BUS PI 346830 BUS PL S S T S N P BUS 2 1 230Vac 3 4 6 0 0 0 0322 06 IP30 PRI230V 50 60Hz 260mA BUS 2 1 27V 1 2A PRI MOD P N ON OFF A To activate the function select the correspon...

Страница 33: ...internal unit PS BUS TK BUS PI 346830 BUS 2 1 230Vac 346000 0322 06 IP30 PRI 230V 50 60Hz 260mA BUS 2 1 27V 1 2A PRI ON OFF MOD P N BUS PL S S A T S N P ON OFF MOD P N BUS BUS 344192 A Door lock push...

Страница 34: ...able level is reached Should the whistle persist adjust the loudspeakers volume in order to eliminate the trouble If the volume is too low level then increase first the potentiometer of the loudspeake...

Страница 35: ...key briefly The LED goes out Press the Connection key to answer the call The connection LED lights up During the conversation you can activate the PUSH TO TALK function Press the Connection key for at...

Страница 36: ...A Via Messina 38 20154 Milano Italy www bticino com BTicino SpA reserves at any time the right to modify the contents of this booklet and to communicate in any form and modality the changes brought to...

Отзывы: