manualshive.com logo in svg
background image

User and installation manual

www.bticino.com

Sfera Proximity Reader

353200

Содержание Sfera video kit

Страница 1: ...User and installation manual www bticino com Sfera Proximity Reader 353200 ...

Страница 2: ...Sfera Proximity Reader User and installation manual ...

Страница 3: ...anager master badge 13 New manager master badge 13 Deleting the manager master badge 15 Passepartout badge 16 New passepartout badge 16 Deleting passepartout badges 18 Resident badge 19 New resident badge M 00 19 Deleting resident badges M 00 21 New apartment master badge M 01 23 Deleting the apartment master badge M 01 25 New resident badge M 01 26 Deleting resident badges M 01 28 Reset 28 Config...

Страница 4: ... installation manual General information The Sfera Proximity Reader must only be used with BTicino 2 wire digital systems Front covers that may be used with the Sfera BTicino Proximity reader Front cover 353205 Front cover 353201 02 03 ...

Страница 5: ...bidden Installing the units near liquids and powders is forbidden Installing the units near heat sources is forbidden Installing the units near harmful gases metal dusts or similar is forbidden Fastening the units on unsuitable surfaces is forbidden Risk of devices falling because the surface on which they are installed collapses or inappropriate installation Switch the power supply OFF before any...

Страница 6: ...d installation manual 1 2 3 4 5 1 Programming reset pushbutton 2 Mini USB programming connector 3 Red LED on steady access denied or programming error 4 Green LED on steady access granted or programming successful 5 Antenna Front view ...

Страница 7: ... 1 Connection to the door lock CP P1 and tamper CP P2 future application pushbutton 2 Local relay contacts 3 Connection to the BUS 4 Connector for the connection to subsequent modules 5 Connector for the connection to previous modules 6 Configurator sockets Back view ...

Страница 8: ...8 Sfera Proximity Reader User and installation manual 1 2 3 Installation Caution Installation configuration starting up and maintenance must be performed exclusively by qualified personnel Mounting ...

Страница 9: ...9 Sfera Proximity Reader User and installation manual 4 5 6 ...

Страница 10: ...10 Sfera Proximity Reader User and installation manual 7 8 9 10 1 2 3 4 Disassembling ...

Страница 11: ...11 Sfera Proximity Reader User and installation manual 5 5 7 8 6 ...

Страница 12: ...other codes It can only be used for programming not for access APARTMENT MASTER Once the apartment badge has been defined this can be used to program the badges of the resident of that apartment It can only be used for programming not for access PASSEPARTOUT It can be used to open the door lock the entrance panel is associated to It s not linked with any apartments It can only be used for access n...

Страница 13: ...pted by means of audible signals and the switching on of the green LED The transmission of an unrecognised badge or a programming error e g memory full or badge already used will cause the interruption of the programming procedure This interruption is confirmed by a long beep and the red LED coming on New manager master badge 2 Release the key and move the system management key card close to the r...

Страница 14: ... the programming pushbutton or wait 30 seconds to exit the programming procedure A short beep and the switching off of the LED confirm that the programming sequence has been completed The Sfera Proximity Reader is ready for normal operation The programming sequence must start within 30 seconds from the moment the programming key has been pressed and must be carried out in one stage ...

Страница 15: ...e pushbutton the device emits 1 beep per second and a long beep after ten seconds The red LED flashes and then switches off to confirm that the deletion has been performed The procedure will delete all the stored manager master badges To stop the deletion procedure release the programming pushbutton before the extended beep To only delete a specific badge use the TiSferaDesign software ...

Страница 16: ...ion of an unrecognised badge or a programming error e g memory full or badge already used will cause the interruption of the programming procedure This interruption is confirmed by a long beep and the red LED coming on 2 Move a new passepartout key card close to the reader for registration The flashing of the green LED and a short beep confirm that the passepartout badge has been saved 1 Move the ...

Страница 17: ...and quickly release the programming pushbutton or wait 30 seconds to exit the programming procedure A short beep and the switching off of the LED confirm that the programming sequence has been completed The Sfera Proximity Reader is ready for normal operation The programming sequence must start within 30 seconds and must be carried out in one stage ...

Страница 18: ...nd the green LED starts flashing Repeat the operation three times in succession Wait 5 between this operation and the next The device emits a long confirmation beep The red LED flashes and then switches off to confirm that the deletion has been performed The procedure will delete all the saved passpartout and apartment master badges To only delete a specific badge use the TiSferaDesign software ...

Страница 19: ...been accepted or deleted through audible signals and the switching on of the green LED The transmission of an unrecognised badge or a programming error e g memory full or badge already used will cause the interruption of the programming procedure This interruption is confirmed by a long beep and the red LED coming on 1 Place a manager master badge close to the reader the reader emits a short beep ...

Страница 20: ... key card 4 You can register more resident key cards up to 5 one after the other 5 Press and quickly release the programming pushbutton or wait 30 seconds to exit the programming procedure A short beep and the switching off of the LED confirm that the programming sequence has been completed The Sfera Proximity Reader is ready for normal operation The programming sequence must start within 30 secon...

Страница 21: ...the system management key card close to the reader The device emits a beep and the green LED starts flashing M 00 managing residents using the manager master 2 Using the keypad 352000 352100 or display 352500 module select the apartment to which to associate the resident key card the reader will emit a beep to confirm ...

Страница 22: ...rmation beep The red LED flashes and then switches off to confirm that the deletion has been performed The procedure will delete all the stored resident badges To only delete a specific badge use the TiSferaDesign software 3 Use the previously used system management key card to confirm the cancellation ...

Страница 23: ...the reader emits a short beep and the green LED starts flashing The programming procedure starts New apartment master badge M 01 M 01 managing residents using the apartment master 2 Using the keypad 352000 352100 or display 352500 module select the apartment to which to associate the resident key card the reader will emit a beep to confirm ...

Страница 24: ... and a short beep confirm that the apartment master badge has been saved The green LED remains on for 2 seconds and then switches off A short beep and the switching off of the LED confirm that the programming sequence has been completed The Sfera Proximity Reader is ready for normal operation The programming sequence must start within 30 seconds and must be carried out in one stage ...

Страница 25: ...p and the green LED starts flashing Repeat the operation three times in succession The device emits a long confirmation beep The red LED flashes and then switches off to confirm that the deletion has been performed The procedure will delete all the saved passpartout and apartment badges saved To only delete a specific badge use the TiSferaDesign software M 01 managing residents using the apartment...

Страница 26: ...reader the reader emits a short beep and the green LED starts flashing The programming procedure starts New resident badge M 01 M 01 managing residents using the apartment master 2 Move a new resident key card close to the reader for registration The flashing of the green LED and a short beep confirm that the resident badge has been saved ...

Страница 27: ...nd quickly release the programming pushbutton or wait 30 seconds to exit the programming procedure A short beep and the switching off of the LED confirm that the programming sequence has been completed The Sfera Proximity Reader is ready for normal operation The programming sequence must start within 30 seconds and must be carried out in one stage ...

Страница 28: ...t the power supply BUS If it is necessary to delete all previously saved badges It is also possible to reset the Sfera Proximity Reader and delete all the previously set modules 1 Disconnect the power supply BUS press and hold down the programming pushbutton and then reconnect the power supply Press and hold down the pushbutton until you hear an extended beep The red LED comes on steady for 4 seco...

Страница 29: ...ation performed using the TiSferaDesign software or to update the firmware connect the Sfera Proximity Reader to the PC using a USB miniUSB cable When updating the software the device must be powered The Sfera Proximity Reader connected using an USB cable is recognised by the PC as a virtual port VIRTUAL COM Connection to the PC ...

Страница 30: ...o Spa reserves at any time the right to modify the contents of this booklet and to communicate in any form and modality the changes brought to the same BTicino SpA Viale Borri 231 21100 Varese www bticino com ...

Отзывы: