background image

1

HA/HB/L4619

24/03/2016

BT00056-c-

4

1

3

2

L4619

HA/HB4619

115 mm

4 mm

4 mm

10 mm

10 mm

100 mm

100 mm

92 mm

93 mm

70 mm

EN

1. 

Reset key

2. 

LED: if the TEST or RESET pushbutton is press for 1 second, the LED will normally 
flash twice; if the battery is exhausted the LED will only flash once

3. 

Flooding probe

4. 

TEST pushbutton

Radio flooding 

detector

Legend

Dimensional data 

Power supply:  

Battery 3 V type CR2032

Operating temperature:  

5 – 40°C

Minimum battery duration:  

2 years

Radio frequency:  

868 MHz

Range:  

100 metres free field 

(metal, concrete walls and metal plates reduce coverage)

Modulation:  

FSK

Technical data 

Description

This device generates an alarm signal when the contacts of the corresponding sensor make 
contact with water.
The signal is then processed by the alarm central unit, which activates the siren and the 
Telephone communicator (if installed), for sending a telephone message.
Better protection can be ensured by installing a relay actuator within the Burglar-Alarm 
system, which will order an electrovalve to shut off the main water supply in case of flooding.
Two front pushbuttons can be used to interrupt the alarm signalling and to test the operation 
of the sensor.

Items HA/HB4619 and L4619 comply with the essential requirement of directive 1999/5/CE as 
they meet the following standards:
- ETSI EN301 489-3
- ETSI EN300 220-3
Year of approval of the CE mark in accordance with the above directive: 2007

Conformity declaration

Flooding detector HA4619 with 

front cover plate

Front view

Отзывы: