Procedure for wired devices:
1. Press and hold down the reset pushbutton* until the LED turns red.
Now release the pushbutton.
The LED flashes green, then turns red and then it goes off.
2. Press and hold down the reset pushbutton* until the LED starts flashing red.
Now release the pushbutton.
The reset has been done
Warning
: a short accidental pressure of the reset pushbutton, starts the association (green LEDs are ON).
Press quickly and at the same time the two keys of the Master wireless In&Out scenario control to end it.
2
2
*Note
: For some aesthetic series, remove covers or plates to access the reset button
*Note
: For some aesthetic series, remove covers or plates to access the reset button
Reset to the factory settings
Warning
: this procedure completely dissociates the device from the smart electric system.
Warning
: never reset the Master wireless In&Out scenario control; in case of reset, start the association
with the zigbee network by quickly pressing the Gateway reset pushbutton, and then press and release
a key of the Master wireless In&Out scenario control and wait for the association to take place (the
control key flashes green for a few seconds and then turns off).
Procedure for wireless controls: