6
A14,4 - 18 SLG M-A
................14,4 V, 18 V
..............................6 A
.......................30/50 min
..................26/59/90 min
................+5°...+40°
..........................703 g
TECHNICAL DATA
BATTERY CHARGER
Voltage range ..........................................................................................
Quick charge current ...............................................................................
Battery charging time with 14.4 V / 1.5/3.0 Ah.........................................
Battery charging time with 18V / 2.0/5.0/9.0 Ah.......................................
Recommended ambient charging temperature .......................................
Weight according EPTA-Procedure 01/2003 ...........................................
WARNING! Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may result in electric
shock, fi re and/or serious injury.
Save all warnings and instructions for future reference.
SAFETY INSTRUCTIONS
Do not dispose of used battery packs in the household refuse or by
burning them. BTI off er to retrieve old batteries to protect our
environment; please ask your sales representative or our service line
at 07940 / 141-141.
Only the following battery packs can be charged with this charger:
Battery Cat. No.
DC Volts
Cell type
Capacity
Cell No.
A14,4V -1,5Ah
14,4 V
Li-Ion
≤ 2.0 Ah
4
A14,4V -3,0Ah
14,4 V
Li-Ion
≤ 3.0 Ah
2 x 4
A14,4V -4,0Ah
14,4 V
Li-Ion
≤ 4.0 Ah
2 x 4
A18V -3,0Ah
18 V
Li-Ion
≤ 3.0 Ah
2 x 5
A18V -4,0Ah
18 V
Li-Ion
≤ 4.0 Ah
2 x 5
A18V -2,0Ah
18 V
Li-Ion
≤ 2.0 Ah
5
A18V -5,0Ah
18 V
Li-Ion
≤ 5.0 Ah
2 x 5
A18V -9,0Ah
18 V
Li-Ion
≤ 9.0 Ah
3 x 5
Do not try to charge non-rechargeable batteries with this charger.
Do not store the battery pack together with metal objects (short circuit
risk).
No metal parts must be allowed to enter the battery section of the
charger (short circuit risk).
Never break open battery packs or chargers and store only in dry
rooms. Keep dry at all times.
The battery clamps of the charger are fed by the mains supply. Do not
touch the tool with conducting objects.
Never charge a damaged battery pack. Replace by a new one.
Before use check machine, cable, and plug for any damages or
material fatigue. Repairs should only be carried out by authorised
Service Agents.
This appliance is not intended to be used
or cleaned by persons with reduced
physical, sensory or mental capabilities,
or lack of experience or knowledge,
unless they have been given instructions
concerning the safe use of the appliance
by a person legally responsible for their
safety. They should be supervised whilst
using the appliance. Children shall not
use, clean or play with this appliance,
which when not in use should be secured
out of their reach.
Warning!
To reduce the risk of fi re, personal injury, and product
damage due to a short circuit, never immerse your tool, battery pack or
charger in fl uid or al-low a fl uid to fl ow inside them. Corrosive or
conductive fl uids, such as seawater, certain industrial chemicals, and
bleach or bleach containing products, etc., Can cause a short circuit.
SPECIFIED CONDITIONS OF USE
The quick charger can charge BTI Li-ion batteries from 14.4 V - 18 V.
Do not use this product in any other way as stated for normal use.
MAINS CONNECTION
Connect only to single-phase AC current and only to the system
voltage indicated on the rating plate. It is also possible to connect to
sockets without an earthing contact as the design conforms to safety
class II.
LI-ION BATTERIES
The rechargeable batteries are partially charged. The LED on the
battery indicates the state of charge.
If it is not used for long periods, the rechargeable battery will switch to
the non-operative state.
When fully discharged the rechargeable battery switches off
automatically (depth discharge not possible).
Under extreme circumstances, the internal temperature of the battery
could become to high. If this happens, the battery will shut down.
Place the battery on the charger to charge and reset it.
The state of charge can be read by pressing the button on the
rechargeable battery. The battery can be left in the electric tool while
the reading is taken but it must be switched off at least one minute
beforehand (otherwise the display will be inaccurate). The number of
LEDs illuminated indicates the state of charge. A fl ashing LED
indicates a max. power reserve of 10%.
As a general principle, if the electric tool should fail to work after
inserting the rechargeable battery, then the battery should be plugged
into the charger. The displays on the battery and charger will then
provide information about the condition of the battery.
In low temperatures work may continue at reduced output.
CHARACTERISTICS
After inserting the battery into the reception of the charger the battery
will automatically be charged (red control lamp is illuminated
continuously)
When a hot or cold battery pack is inserted into the charger (fl ashing
red lamp), charging will begin automatically once the battery reaches
the correct charging temperature (0°C...65°C). The max. charging
current is fl owing when the temperature of the Li-Ion-battery is between
0°C and 65°C.
The battery’s charging time is between 1 min and 26 min (at 2,0 Ah),
depending on the state of discharge.
Once the battery is fully charged, the LED on the charger changes
from red to green.
Remove the battery pack from the tool for charging when convenient
for you and your job. BTI batteries do not develop a “memory” when
charged after only a partial discharge. It is not necessary to run down
the battery pack before placing it on the charger.
As a general practice, it is best to unplug battery chargers and remove
batteries when not in use. No battery pack damage will occur,
however, if the charger and battery pack are left plugged in.
If both LEDs fl ash alternately then the rechargeable battery is either
not fully pushed in or there is a fault with the battery or charger. Take
the charger and battery out of use immediately for safety reasons and
have them inspected by a BTI customer service centre.
ENGLISH
445 791 - BTI-A14,4-18SLG.indd 6
445 791 - BTI-A14,4-18SLG.indd 6
07.09.2017 10:42:03
07.09.2017 10:42:03