4.1.2
Transmitter Setup
The purpose of the setup is to set the mounted transmitter into operation with a
basic calibration. This concerns the mounting position, blade type, tag number,
pulp type calibration constants and the span of the output signal.
NOTE!
Before transmitter setup is done, a shear force trim must be performed. See
section 5.2.3:
.
1. Power up the JCT-1200.
2. Press
Menu (F1)
, step down through the menu tree to the
Shear force trim
window, note the
Raw signal
value.
3. Select the
air
option and press
Edit (F3)
.
4. Enter the
Raw signal
value and press
OK (F1)
.
5. Press
Menu (F1)
, step down through the menu tree to the
General set-
tings
window, select the
Blade type
option and press
Edit (F3)
.
6. Enter the correct blade. Press
OK (F1)
.
7. Select
Tag
, press
Edit (F3)
, enter the correct tag. Press
OK (F1)
.
8. Press the
Menu (F1)
key twice to step up through the menu tree.
The main menu window opens.
9. Go to the
Basic calibration
window for
Range 1
, select the
K1
option and
press
Edit (F3)
.
10. Enter the appropriate value from the calibration table. See section 7.7:
.
Press
OK (F1)
.
11. Select the
K2
option and press
Edit (F3)
. Enter appropriate value from the
same calibration table as in step 9. Press
OK (F1)
.
12. Select the
4mA
option and press
Edit (F3)
. Enter correct percentage for
4mA. Press
OK (F1)
.
13. Select the
20mA
option and press
Enter (F2)
. Enter correct percentage for
20mA. Press
OK (F1)
.
14. Transmitter setup is completed.
IMPORTANT!
Note all entered values and save as backup.
4.1.3
Set Lab Sampling Time
The
LabSamplTime
value should correspond to the actual time it takes to col-
lect the lab sample from the process pipe.
1. Press
Menu (F1)
, step down through the menu tree to the
General set-
tings
window, select the
LabSamplTime
option and press
Edit (F3)
.
2. Enter correct time. Press
OK (F1)
.
Содержание Pulptec SBT-2400
Страница 1: ...USER MANUAL Pulptec BTG Pulp Paper Sensors AB SBT 2400 Static Blade Consistency Transmitter M2041 5en ...
Страница 12: ...1 4 Type Sign Explanation 6 SBT 2400 Product Introduction M2041 5en BTG 2006 ...
Страница 26: ...3 6 Mounting of Optional Accessories 20 SBT 2400 Installation Instructions M2041 5en BTG 2006 ...
Страница 58: ...5 4 Troubleshooting 52 SBT 2400 Service Instructions M2041 5en BTG 2006 ...