![BTEK T419S Скачать руководство пользователя страница 68](http://html.mh-extra.com/html/btek/t419s/t419s_service-manual_2825011068.webp)
68
T419S Indicator Service Manual
7
Communication port protocols
7.4.2 Ethernet/IP Implicit Messaging:
AWTX Assembly Instance and Size
INPUT/OPUTPUT SIZE: Is the number of elements (items) configured in the indicator
for the data IN and OUT not the number of bytes.
Note each register holds 2-bytes or 1-word. If a 4-byte or 2-word data type is used 2-
registers are required for each item. This makes the starting register number for each
item skip a register number between items.
Assembly
Instance
Size
Input
100
Refer to the number of items configured for Out
Configuration at the indicator
Output
112
Refer to the number of items configured for In
Configuration at the indicator
Configuration
128
0