6.4
Ports menu
Type
Below is a table showing the choices
for the Type, a description and a range
of values for that data type.
Value
This stands for the network token value
to be assigned to the inbound data
memory register. Key in the value for
the network token you want from the
table above and press
ENTER
to
accept the displayed choice …
Repeat the process for any other
inbound memory registers you want to
configure.
Scale
Choose from connected scales.
Out
This stands for outbound data configuration. This menu item
is exactly like the
in
menu item except it is for outbound data.
Follow the same process to set up the 32 memory registers.
6.4.6 Printer
Prtr 1
You can choose to set up this printer or
Prtr 2
. The setup procedure is the
same.
DATA TYPE TABLE
Indicator Terminology
Typical PLC Terminology
Data TYPE Size
SINT8 - 1 byte
CHAR / SBYTE
8 Bits (Signed Value / -127 to 127)
UNIT8 - 1 byte
BYTE / UBYTE
8 Bits (Unsigned Value / 0-255)
SINT16 - 2 byte
SHORT / SINT
16 Bits (Signed Value /-32767 to 32767)
UNIT16 - 2 byte
WORD / UINT
16 Bits (Unsigned Value / 0 to 65535)
SINT32 - 4 byte
LONG / SDINT
32 Bits (Signed Value / -2,147,483,647 to 2,147,483,647)
UNIT32 - 4 byte
DWORD / UDINT
32 Bits (Unsigned Value / 0 to 4,294,967,295)
FLOAT - 4 byte
REAL
32 Bits (Signed Decimal Value / 1.0E-37 to 1.0E37
STRING - 1 byte/char
STRING
Length Parameter setting
The Type and order of the Values selected must coincide with the configuration of the
PLC register setup. Consult with the site IT specialist.
The
Printer
menu is used when the indicator is interfaced with one of the printers
listed in the
Brand
submenu. This is necessary to ensure all the appropriate control
codes are added to the selected print format.
If either PRTR1 or PRTR2 selections are enabled then the port that is Binded may
occasionally send out a set of random characters to test for a connected printer. Be
sure to disable these settings if the indicator is not connected to one of the printer
brands listed.
Содержание T419S
Страница 1: ...AWT35 501788 Issue AC T419S Indicator Service Manual original instructions AMERICAS CONFIDENTIAL ...
Страница 2: ...BTEK_T419S_s_en_501788 book 2019 B TEK All rights reserved ...
Страница 118: ...118 T419S Indicator Service Manual ...
Страница 130: ...130 T419S Indicator Service Manual ...
Страница 134: ...134 T419S Indicator Service Manual Last 28 Temp 28 ...
Страница 135: ......
Страница 136: ...B TEK Scale LLC 1510 Metric Ave SW Canton OH 44706 3088 ...