![BTCPower EVSE 200 KW Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/btcpower/evse-200-kw/evse-200-kw_installation-and-user-manual_2824943018.webp)
This document is the
Property of Broadband Telecom Power Inc.
and
will not be copied, reproduced, or used as the basis for sale or
manufacture of apparatus without written permission.
BTCPower 200 KW EVSE Installation manual
Rev K
Page 18 of 26
Interlock –
18 gage twisted pair, shielded. Suggested PN McMaster
4.
Output Coupler (Part of Dispenser)
CCS-1, Huber + Suhner high powered liquid cooled coupler.
•
Please refer to Huber + Suhner specification for additional details.
•
Cable Length:
o
4.5 meter outside length (standard)
o
Optional longer length available
•
Cable Management System:
o
None. This will be a non-retractable cable system
5.
Electrical and communication service connection
Dispenser requirements.
The dispenser requires the following:
a. DC input from the tower.
b. Auxiliary power from main circuit panel. The auxiliary power is used to power the heat
exchanger as well, payment system as well as display module.
c. Communication conduit between the tower and the dispenser. For this purpose, the BTC
dispenser and tower utilize optical wire for communication.
Tower (converter) requirements.