12- 38
Service Manual
LWE130
© BT Europe AB
Electrical system – 5000
Parameters & adjustments
T-code
Valid from serial number
Date
Order number
675
914369-
2005-09-23
226057-040
12.10.3 List of parameters
NOTE!
Before changing any parameters, ensure you have read and under-
stood the procedures for viewing and setting parameters in the sec-
tions Adjusting parameters on page 37.
See also section Speed limitation on page 26 for information regarding
the maximum speeds of the truck.
Table 13: Overview of parameters
Parameter
name (display)
Function
Min.
Max.
Std.
Note
ACC.DELAY
Determines accelera-
tion ramp time.
0
9
6
A= acceleration
DECELER.DELAY
Determines decelera-
tion ramp when
speed control is
reduced.
0
9
5
D= deceleration
RELEASE BRAK-
ING
Determines neutral
braking intensity.
0
9
5
B= braking intensity
INVERSION BRAK-
ING
Determines reverse
braking intensity.
0
9
9
B= braking intensity
CUTBACK SPEED
3
Determines truck’s
max. speed.
0
9
9
S= maximum speed
CHECK UP DONE
Resets service hours
counter to zero.
-
-
OFF
CHECK UP TYPE
Selects type of serv-
ice warning.
0
3
NONE
CHECK UP HOURS
Determines “Time to
next service”.
0
9
2
9:
0:
A
9:
0:
D
0:
9:
B
0:
9:
B
0:
9:
S