Electrical System – 5000 LWE 180/200 LPE 200
Parameters
Order number
Date
Valid from serial number
T-code
225553-040
2005-05-11
723984-
660, 661, 662, 497
© BT Europe AB
Service Guide
LWE180, LWE200, LPE200, LPE240
9- 41
Recommendation on parameter setting for freely
ventilated batteries
WARNING !
The service life of the battery will be reduced if the value of parameter
21 is set at too high a value. The standard setting of parameter 21 is
set for normal truck handling. Other applications may require a differ-
ent setting of parameter 21. Check that the parameter setting is the
correct one using the instructions below.
Parameter 21
Battery size
LWE180, LWE200,
LPE200-6
Battery size
LPE200-8
Less dis-
charge
Greater dis-
charge
1
2
3
4
5
260Ah - 320Ah
Standard value
6
190Ah - 250Ah
7
120Ah - 180Ah
260Ah - 320Ah
Standard value
8
190Ah - 250Ah
9
120Ah - 180Ah
10
11
12
13
14
15
16
17
18
19
20