Electrical System – 5000 LWE 180/200 LPE 200
Parameters
T-code
Valid from serial number
Date
Order number
660, 661, 662, 497
723984-
2005-05-11
225553-040
Parameter 20
You decide yourself what the hour meter will show.
1A = Key time
2b = Movement time
3c = Drive motor time
4d =Pump motor time
5s = Time for service
Parameter 21
You must specify the type of battery the truck is equipped with.
In order to set the meter for the battery’s level of discharge, the follow-
ing should be taken into account:
•
Acid concentration when the battery is fully charged, to check the
grade of the battery. Must be between 1.27-1.29.
•
When the lifting capacity is disconnected (the battery is 80 % dis-
charged), the value must be close to, but not below, 1.14.
The acid concentration can vary depending on the battery make.
Fork lowering or driving backward or AOM
26
Fork lowering or driving forward or driving
backward or AOM
27
Fork lift or fork lowering or AOM
28
Fork lift or fork lowering or driving forward or
AOM
29
Fork lift or fork lowering or driving backward
or AOM
30
Fork lift or fork lowering or driving forward or
driving backward or AOM
31
Table 3: Option 3 – Choice of movement