Electrical System – 5000 LWE 180/200 LPE 200
Parameters
Order number
Date
Valid from serial number
T-code
225553-040
2005-05-11
723984-
660, 661, 662, 497
© BT Europe AB
Service Guide
LWE180, LWE200, LPE200, LPE240
9- 35
The parameter symbol flashes.
.
•
Enter the sub-parameter value by repeatedly operating the speed
control L1 in either direction. See Table 1: for more information.
•
Press the S18 horn button once to confirm the new setting.
The parameter symbol is lit (i.e. stops flashing).
•
Switch off the truck by pressing
on the keypad.
The non-configurable option is now activated.
•
Check that the function works correctly before the truck is put back
in operation.
P
Parameter #16 to 19 configurable optional functions
Parameter no. #16, #17, #18 & #19 can be adjusted to activate up to a
maximum of 4 pre-programmed functions and configure these to suit
optional equipment or customisation of the truck. See “Table 2:List of
configurable optional functions” on page 37. These are thus called the
configurable optional functions.
•
Each parameter can be programmed to cover a specific optional
function.
•
Each optional function can have up to 4 independent variables asso-
ciated with it.
•
Each independent variable has a value you can change to configure
the function.
Table 1: Parameter #15 Non-configurable option
Sub-p
a
rameter no.
Function name
Value
Note!
Func
tion ON
Func
tion OFF
Basi
c setting
1
"Turtle" function
1
0
0
2 to 9
For future use
-
-
-