Factory Default Settings
7
CLS Pro 600 – Line and Contrast Sensor
81/108
DANGER
Danger from the power supplies!
You are only allowed to open the sensor if the power supply has
been switched off!
Setting up the Terminating Resistor:
1. Switch-off the power to the sensor.
2. Unscrew the stopper in the sensor enclosure
3. Check the
S3
switch setting. The
S3
switch must be set to the
ON
position.
4. Switch
S3
to the
ON
position if necessary.
5. Screw the stopper back into the sensor enclosure.
6. Switch on the mains voltage.
7.2.2
Control Panel Terminator Resistor
The control panel’s internal terminator resistor is switched on or
off using switch
S3
. The current setting is displayed in the
System
info
sub-menu as
Can Resistor Commander
(
see Section 6.7.5
).
The
S3
switch is mounted behind stopper C on the back of the
control panel.
Fig. 42: Switch S3
NOTICE
Caution!
The terminating resistor should only be switched off after first ob-
taining agreement from the manufacturer!
Switch S3
Function
OFF
Internal terminating resistor switched off