5
Commissioning
38/108
CLS Pro 600 – Line and Contrast Sensor
5
Commissioning
NOTICE
Caution
Only qualified and trained personnel are permitted to undertake
the commissioning!
DANGER
Danger from the power supplies!
You are only allowed to open the sensor or other components if
the power supplies have been switched off!
Requirements:
■
The web guiding system has been fully wired in, i.e. the cable
connections between the specific web guiding components
have been made.
■
The sensor is connected to the power supply.
■
The sensor switches (see 4.4 and 7.1.1) and the panel (see
7.1.2) have been set up for the appropriate application.
■
The following information window will be superimposed on the
screen if the panel cannot make bus contract with the sensor:
The following are displayed:
■
The panel’s node number on the bus (
Commander Node
)
■
The synchronization status (
SYNC
)
■
The module status (
Modulstate
)
■
Whether the sensor has been detected on the bus (
Sensor
at ...
)
■
Whether the terminator resistor has been set up (
Resistor
)
There must always be one sensor and one panel with correspond-
ing nodes present on the bus (e.g. sensor = 41 and panel = 111) so
that the system can work correctly. If the sensor is not detected
then this will be indicated, as the bus connection has not been
made. Always check the connection cable and the plug in this
case. Furthermore, you can also read whether the terminator res-
istor has been set up correctly or not.