Assembly
3
CLS Pro 600 – Line and Contrast Sensor
25/108
3.3
Installing the Control Panel
3.3.1
General Information
This Chapter describes the procedure for installing the control
panel when using the sensor with control panel removed.
Please note:
Strong electro-magnetic fields in the immediate vicinity
of the control panel can result in malfunctions. You must
ensure that the control panel is not mounted close to
components that use mains power or power lines when
installing in a control console or a control station. Always
maintain a minimum clearance of 100 mm!
Installation Versions
The control panel enclosure enables the following installation ver-
sions to be used:
1.
Wall installation
The control panel is secured to a level surface. Procedure:
See
chapter 3.3.3
.
2.
Console installation
The control panel is installed in an existing on-site control con-
sole or a control station. Procedure:
See chapter 3.3.4
.
Please note:
A CLS Pro 600 securing kit, which is available as an op-
tion, is needed to install the control panel in a control
console (BST eltromat Order-No. 133 459).
Cable Extension
An optional cable extension is needed to connect the control
panel to the sensor. Cable extensions are available in the follow-
ing lengths:
Cable length
BST eltromat Order-No.
2 m
131 993
5 m
131 994
10 m
131 995
Please note:
It is also possible to combine different cable lengths. The
maximum permitted full length of 20 m between the
sensor and the control panel must never be exceeded!
3.3.2
Dismantling the Holder
The holder must be removed before the control panel and holder
can be removed.