BT603 Users Manual
9.2.
Graphic
Test
This test shows the induced signal in real-time plots. The plot and its operation is similar to Figure 11
①
②
③
④
⑤
⑥
Figure 21 Graphic Test for Crosstalk
①
To change the input channel and measuring channel, press
. (See Figure 19)
②
Mode indicator for
. It also shows the current setting. To change its mode, press
. (See Section 8.6)
③
Distance (between Cursor1 and Cursor2) or VOP. To swap them, press
.
④
Cursor1 and Cursor2. To move them, use with its mode set to “CURSOR1” and “CURSOR2” respectively. (See Section 8.6)
The cursors must be located at the beginning of reflections.
⑤
Magnitude of crosstalk near the tester end; this corresponds to Near End Crosstalk.
⑥
Magnitude of crosstalk nearer the far end of the cable; this corresponds to Far End Crosstalk.