background image

On the BLU-6 there are connections 

labeled; GND, SELECT, UP & DOWN. 

The GND terminal is connected back to 

the ‘C’ or Common terminal on the Control 

Inputs of the Soundweb device. The ‘SELECT’ terminal is for 
the Source Select and is connected back to a numbered 
Control Input on the Soundweb device. The ‘UP’ terminal is 
for the Level Up and is connected back to a second 
numbered Control Input on the Soundweb device. The 
‘DOWN’ terminal is for the Level Down and is connected 
back to a third numbered Control Input on the Soundweb 
device. Each Soundweb London chassis can support 
connections for up to four BLU-6 or sw9015US controllers.

Note: The Soundweb device must be in 2-wire mode when 
using these controllers. This is the default mode.

These parameters need to be assigned to Control Inputs within the HiQnet 
London Architect file. 

To do this:
Open the Design tree.
Expand the Devices category
Expand the Device Type category
Expand the Named Device category
Expand the Default Config category
Expand the Control Ports category

You will now see the Control Ports displayed. You will see the twelve Control 
Inputs and six Control Outputs and any parameter assignments made to 
them. 

To create a new assignment:
Open the Default Control Panel where the control resides. Drag the control from that panel 
over to the Design tree and drop it on the Control Input. During the drag, the cursor will 
change to a ‘+’ symbol when you are over a valid drop location. You can expand a Control 
Input to view what State Variable is attached. To delete an existing parameter assignment, 
you can simply drag a new parameter on to the Control Input and it will make a new 
assignment or you can right click on the Control Port and choose ‘Delete’.

To download this HiQnet London Architect file, visit our web site

bssaudio.com

Connecting the BLU-3, BLU-6, 

sw9012US and sw9015US

2-wire mode

Отзывы: