18
Controls and connections
10.5 Signal level
indicators
The SIG LED indicated that a signal is being received within that band, and the
PEAK LED warns of the possible onset of system overload. The SIG LED will
not light for signals below peak level of -20dB, and the PEAK LED lights for
signals in excess of +10dB. This does not represent the maximum signal level
within the
FDS-318
(which is +20dBv), but rather that the sound system is
being driven very hard. For a more detailed explanation of this,
refer to section
11.6
.
10.6 Select mode
LED
These LEDs show which mode of operation has been selected by the rear panel
SELECT MODE switch. They also point toward the correct control knob
function, as this varied dependant on the mode selected.
10.7 Rear panel
switch LEDs
These LEDs show the status of the CD EQ and MONO LOW switches on the
rear panel.
10.8 Mains power
fuse
The mains power fuse is 20mm long, and rated T250mA for 120V settings and
T200mA for 240V settings. For continued protection, ALWAYS replace this fuse
with the correct value.