background image

DS4800

Reference Manual

BSR idware GmbH

Jakob-Haringer-Str.3

A-5020 Salzburg
Web: www.bsr.at            

Содержание BSR00034

Страница 1: ...DS4800 Reference Manual BSR idware GmbH Jakob Haringer Str 3 A 5020 Salzburg Web www bsr at...

Страница 2: ...Datalogic and the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S A and the E U ID NET Genius and X PRESS are trademarks of Datalogic Automation S r l A...

Страница 3: ...RODUCTION 18 2 1 Product Description 18 2 1 1 Indicators 19 2 2 ID NET 19 2 2 1 How To Setup Configure the Scanner Network 21 2 3 X PRESS Human Machine Interface 22 2 3 1 Diagnostic Indication 22 2 3...

Страница 4: ...s 71 5 5 1 Code Verifier 74 5 6 Outputs 74 5 7 User Interface Host 75 6 TYPICAL LAYOUTS 76 6 1 Point to Point 76 6 2 Pass Through 78 6 3 ID NET 80 6 4 RS232 Master Slave 85 6 5 Multiplexer Layout 86 7...

Страница 5: ...v INDEX 115...

Страница 6: ...vices as well as technical support through its website Log on to www automation datalogic com and click on the links indicated for further information PRODUCTS Search through the links to arrive at yo...

Страница 7: ...the threshold for its correct scanning speed The laser beam can be switched off through a software command see also the Genius Help On Line WARNING Use of controls or adjustments or performance of pro...

Страница 8: ...s operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful in...

Страница 9: ...however it is also a precision product and therefore before and during installation it must be handled correctly to avoid damage avoid that the scanners hit one another causing damage They should be...

Страница 10: ...x do not weld the scanner into position which can cause electrostatic heat or output window damage do not spray paint near the scanner which can cause output window damage...

Страница 11: ...xi GENERAL VIEW DS4800 1000 Figure A 1 2 3 6 5 POWER ON LED Indicator LEDs Laser Beam Output Window Push Button 4 Display Focus Adjustment 4 2 1 3 5 6...

Страница 12: ...xii DS4800 1100 Figure B 1 2 3 6 5 POWER ON LED Indicator LEDs Laser Beam Output Window Push Button 4 Display Focus Adjustment 4 2 1 3 5 6...

Страница 13: ...xiii DS4800 1005 Figure C 1 2 3 7 6 POWER ON LED Subzero Model Logo Laser Beam Output Window Push Button 5 Display Focus Adjustment Indicator LEDs 4 5 1 4 6 7 2 3...

Страница 14: ...xiv 5 2 1 4 6 7 3 DS4800 1105 Figure D 1 2 3 7 6 POWER ON LED Subzero Model Logo Laser Beam Output Window Push Button 5 Display Focus Adjustment Indicator LEDs 4...

Страница 15: ...dware indicated in Figure 1 In this layout the data is transmitted to the Host on the main serial interface In Local Echo communication mode the RS232 auxiliary interface can be used to transmit data...

Страница 16: ...ternal Trigger B polarity insensitive TX Auxiliary Interface TX V Power Reference External Trigger RX Auxiliary Interface RX V Power Source Inputs SGND Auxiliary Interface Reference I2A Input 2 A pola...

Страница 17: ...25 7 GND Power supply input voltage 1 CHASSIS Cable shield connected to chassis 18 I1A External Trigger A polarity insensitive 19 I1B External Trigger B polarity insensitive 6 I2A Input 2 A polarity i...

Страница 18: ...shown in the figures below Figure 4 Positioning with Mounting Bracket 2 When mounting the DS4800 take into consideration these three ideal label position angles Skew 15 to 30 Tilt 0 and Pitch 0 Assur...

Страница 19: ...take into consideration these three ideal label position angles Skew 15 to 30 Tilt 0 and Pitch 0 The Skew angle refers to the most inclined or external raster line so that all other raster lines assu...

Страница 20: ...n The alternating message on the display shows the mechanical Focus Position 2 Using a screwdriver turn the focus adjustment screw in the desired direction clockwise focus nearer to the scanner or cou...

Страница 21: ...s during the warm up phase GOOD Green This LED confirms successful reading TRIGGER Yellow This LED indicates the status of the reading phase COM Yellow This LED indicates active communication on main...

Страница 22: ...at if needed the above two steps to program up to 10 different barcodes the LEARN LED returns to the blinking state for the next code If more than one barcode is detected in the scan line the Multi La...

Страница 23: ...hat specific barcode green green yellow yellow red READY GOOD TRIGGER COM STATUS SETUP LEARN TEST FOCUS Figure 9 X PRESS Interface Auto Setup Function The procedure is as follows A place the desired b...

Страница 24: ...PRESS Interface Focus Lock Unlock Function The procedure is as follows A enter the Focus Lock function B wait until the Focus locked at message appears on the display indicating the focus position has...

Страница 25: ...run and follow the installation procedure This configuration procedure assumes scanner connection to a CBX100 500 Genius running on a laptop computer is connected to the scanner auxiliary port through...

Страница 26: ...S4800 REFERENCE MANUAL 12 1 1 Select the Create a new configuration button You will be guided through the configuration being asked to define the following parameters a Barcode selection and definitio...

Страница 27: ...RAPID CONFIGURATION 13 1 b Operating mode selection and definition c Digital Outputs configuration...

Страница 28: ...matic operating mode does not require connection to an external Presence Sensor When working in this mode the reader is continuously scanning while the reading phase is activated each time a barcode e...

Страница 29: ...ration as follows Saving the configuration to disk Switching to Advanced mode Sending the configuration to the scanner 3 After sending the configuration to the scanner you have completed the configura...

Страница 30: ...unction by holding the X PRESS push button pressed until the TEST LED is on 2 Release the button to enter the Test mode function Once entered the Bar Graph on the five LEDs is activated and if the sca...

Страница 31: ...st computer using the Host Mode programming procedure by commands via the serial interface See the Host Mode Programming file on the CD ROM Alternative Layouts The ID NET network is a built in high sp...

Страница 32: ...e contact your local Datalogic distributor Some of the main features of DS4800 are listed below ACR4 Advanced Code Reconstruction 4th Generation small dimensions and light weight software programmable...

Страница 33: ...tive even in the absence of data transmission because of polling activity on the Fieldbus network During the reader startup reset or restart phase all the LEDs blink for one second On the back of the...

Страница 34: ...ors All scanners are typically located far away from each other and they use a dedicated presence sensor At the end of each reading phase each scanner transmits its own data message to the host Thanks...

Страница 35: ...prompt to Send updated Network configuration to the Local Device Master choose Yes 4 Then run the NET AUTOSET procedure from the Icon in the Devices Area Genius sets all slave scanners according to th...

Страница 36: ...when in the one of the operating modes On Line Automatic or Continuous are illustrated in par 2 1 1 NOTE Except for the Focus Lock Unlock function the X PRESS functions do not work if the motor or las...

Страница 37: ...M STATUS SETUP LEARN TEST FOCUS READY GOOD TRIGGER COM STATUS SETUP LEARN TEST FOCUS Release button to Exit Release button to enter Test Mode Release button to enter AutoLearn READY GOOD TRIGGER COM S...

Страница 38: ...d barcodes are automatically configured in scanner memory AutoSetup Function Once entered if a barcode label is positioned in front of the scanline the scanner automatically performs the optimal setup...

Страница 39: ...rocess Reset Scanner to Factory Default If it ever becomes necessary to reset the scanner to the factory default values you can perform this procedure by holding the X PRESS push button pressed while...

Страница 40: ...om 000 to 100 Z code content F focus distance in given in centimetres and inches Autolearn Results X X X X X X X X X Y Y D G T A u t o l e a r n O k Z Z X recognized code symbology Y number of digits...

Страница 41: ...tent Y number of codes read G o o d X X X X X X X X X X X Y Y D G T D W W W S S S X code content Y number of digits in the code DGT digits D code direction F forward R reverse U unknown Linear Reading...

Страница 42: ...k Slave address Axx Mux32 Slave address 232 RS232 network Null string Alone no network S N X X X X X X X X X F Z Z Z C M Y Y Y I N X device serial number Z focus position in cm Y focus position in inc...

Страница 43: ...more than 15 Skew This avoids the direct reflection of the laser light emitted by the reader 0 15 35 code surface 5 Figure 5 Oscillating Mirror Skew Angle Otherwise the scanner can be mounted at an a...

Страница 44: ...ese internal components are heated to within their operating temperature range Power up at 35 C can take about 20 minutes before the scanner is ready to read barcodes During this time the laser motor...

Страница 45: ...odule STD IP65 93ACC1810 93ACC1811 BM400 DeviceNet Module IP65 93ACC1814 BM500 510 520 Ethernet IP Module STD IP65 IP54 93ACC1812 93ACC1813 93ACC1840 BM600 CANopen Module 93ACC1815 BM700 Profinet Modu...

Страница 46: ...and all the parts supplied with the equipment are present and intact when opening the packaging the list of parts includes DS4800 reader with cable DS4800 Quick Guide Barcode Test Chart Grade A Genius...

Страница 47: ...holes M5 x 3 for fixture to the U shaped mounting bracket The following diagrams give the overall dimensions of the scanner and mounting brackets and may be used for installation Refer to par 3 2 1 a...

Страница 48: ...0 12 4 2 0 17 Figure 16 L Shape Mounting Bracket Overall Dimensions 71 6 2 82 100 6 3 96 103 4 06 74 2 91 76 9 3 03 3 0 12 108 4 25 30 1 18 64 2 2 53 70 2 76 5 5 0 22 N 2 56 2 20 15 15 45 45 9 0 35 2...

Страница 49: ...M 4 M 4 M 4 87 7 3 45 81 3 19 12 1 0 48 5 2 0 21 41 9 1 65 27 9 1 10 37 1 46 37 8 1 49 34 1 34 7 5 0 30 10 0 39 13 0 51 42 1 65 42 5 1 67 48 4 1 90 M 5 M 5 5 9 0 23 41 5 1 63 10 0 39 M 5 116 6 4 59 10...

Страница 50: ...4800 Using the DS4800 mounting bracket you can quickly and easily obtain standard mounting positions i e 15 Skew angles for the reader as shown in the following figures Figure 19 Positioning with L Sh...

Страница 51: ...INSTALLATION 37 3 Figure 20 Positioning with U Shape Mounting Bracket Pitch Skew 0 15 45 45 15 alignment marks...

Страница 52: ...DS4800 REFERENCE MANUAL 38 3 Figure 21 DS4800 OM Positioning with U Shape Mounting Bracket Tilt Skew 0 15 45 45 15 alignment marks...

Страница 53: ...e is represented by the value S in Figure 22 Position the reader to assure at least 15 for the Skew angle This avoids the direct reflection of the laser light emitted by the DS4800 Figure 22 DS4800 Sk...

Страница 54: ...DS4800 REFERENCE MANUAL 40 3 The Pitch angle is represented by the value P in Figure 24 Position the reader in order to minimize the Pitch angle Figure 24 DS4800 Pitch Angle P P...

Страница 55: ...100 500 Terminal Block Connectors Input Power Vdc Power Supply Input Voltage GND Power Supply Input Voltage Earth Protection Earth Ground Inputs V Power Source External Trigger I1A External Trigger A...

Страница 56: ...ate jumper in the CBX connection box See the CBX Installation Manual for details 4 2 MAIN SERIAL INTERFACE CAUTION Do not connect to the Main Interface spring clamp terminals if using Host Interface M...

Страница 57: ...es The overall maximum cable length must be less than 15 m 49 2 ft SGND RXD TXD CTS RTS USER INTERFACE SGND TX RX RTS CTS SCANNER Figure 26 RS232 Main Interface Connections Using Hardware Handshaking...

Страница 58: ...nments The CBX pinout follows CBX100 500 Function TX RS485 Transmit Data RX RS485 Receive Data TX RS485 Transmit Data RX RS485 Receive Data SGND Signal Ground RX485 TX485 SGND RX485 TX485 USER INTERFA...

Страница 59: ...e a master device polls slave devices to collect data CBX100 500 Function RTX RS485 Receive Transmit Data RTX RS485 Receive Transmit Data SGND Signal Ground RTX485 SGND RTX485 USER INTERFACE SGND RTX...

Страница 60: ...R Shield to Earth 120 Ohm CBX100 500 Shield floating CBX100 500 Shield floating CBX100 500 SGND Shield RTX RTX SGND Shield RTX RTX SGND Shield RTX RTX Shield floating RS485 HD Termination Resistor OFF...

Страница 61: ...max cable length depends on the baudrate used see the Baudrate Table below For Common Power Connections use only 2 wires ID and ID DC Voltage Power cable Vdc GND should be handled as a signal cable i...

Страница 62: ...etween the Trigger activation and the beginning of data transmission to the Host Max ID NET Response Time 240 220 200 180 160 140 120 100 80 60 40 20 0 Response Time ms Number of Nodes 500 kbps 250 kb...

Страница 63: ...CBX ELECTRICAL CONNECTIONS 49 4 Figure 33 ID NET Network Connections with isolated power blocks...

Страница 64: ...DS4800 REFERENCE MANUAL 50 4 Figure 34 ID NET Network Connections with Common Power Branch Network...

Страница 65: ...CBX ELECTRICAL CONNECTIONS 51 4 Figure 35 ID NET Network Connections with Common Power Star Network...

Страница 66: ...g the Genius utility program or Genius based Host Mode Programming installed from the CD ROM The 9 pin female Auxiliary Interface connector inside the CBX is the preferred connector for device configu...

Страница 67: ...00 Function V Power Source External Trigger I1A External Trigger A polarity insensitive I1B External Trigger B polarity insensitive V Power Reference External Trigger The External Trigger input is use...

Страница 68: ...er Using DS4800 Power EXTERNAL TRIGGER INPUT CONNECTIONS USING EXTERNAL POWER Pulled down to External Input Device Reference Input Signal PNP Photocell Figure 40 PNP External Trigger Using External Po...

Страница 69: ...IONS USING DS4800 POWER Power to Input Device Input Input Device Signal Reference Input Device PNP Input 2 Using DS4800 Power Power to Input Input Device Signal Input Device Reference Input Device NPN...

Страница 70: ...de in the scanner s non volatile Flash memory For more details see the Verifier Parameters in the 2K 4K Family Software Configuration Parameter Guide Help file 4 6 OUTPUTS Two general purpose outputs...

Страница 71: ...Reference Output Device Output Signal Figure 45 Open Collector Output Using DS4800 Power OUTPUT CONNECTIONS USING EXTERNAL POWER Pulled up to External Output Device Power Output Signal Output Device F...

Страница 72: ...ins the pinout for standard RS232 PC Host interface For other user interface types please refer to their own manual RS232 PC side connections 1 5 9 6 9 pin male connector 13 25 14 1 25 pin male connec...

Страница 73: ...voltage 25 7 GND Power supply input voltage 1 CHASSIS Cable shield connected to chassis 18 I1A External Trigger A polarity insensitive 19 I1B External Trigger B polarity insensitive 6 I2A Input 2 A p...

Страница 74: ...in 1 CHASSIS to a common earth ground 5 2 MAIN SERIAL INTERFACE The signals relative to the following serial interface types are available on the input output connector of DS4800 If the interface type...

Страница 75: ...The overall maximum cable length must be less than 15 m 49 2 ft DS4800 7 4 5 3 GND RTS CTS RX TX 2 USER INTERFACE GND CTS RTS TXD RXD 1 Chassis Figure 50 RS232 Main Interface Connections Using Hardwar...

Страница 76: ...nector pinout follows 25 pin Name Function 2 TX RS485 Transmit Data 3 RX RS485 Receive Data 4 TX RS485 Transmit Data 5 RX RS485 Receive Data 7 GND Ground DS4800 TX 2 TX 4 RX 3 RX485 RX 5 TX485 7 GND G...

Страница 77: ...polls slave devices to collect data The connector pinout follows 25 pin Name Function 2 RTX RS485 Receive Transmit Data 4 RTX RS485 Receive Transmit Data 7 GND Ground RTX 2 RTX 4 RTX485 RTX485 7 GND...

Страница 78: ...DS4800 REFERENCE MANUAL 64 5 Figure 55 DS4800 Multidrop Connection to a Multiplexer...

Страница 79: ...ength depends on the baudrate used see the Baudrate Table below For Common Power Connections use only 2 wires 23 and 24 DC Voltage Power cable Vdc GND should be handled as a signal cable i e do not pu...

Страница 80: ...etween the Trigger activation and the beginning of data transmission to the Host Max ID NET Response Time 240 220 200 180 160 140 120 100 80 60 40 20 0 Response Time ms Number of Nodes 500 kbps 250 kb...

Страница 81: ...25 PIN CABLE ELECTRICAL CONNECTIONS 67 5 Figure 57 ID NET Network Connections with isolated power blocks...

Страница 82: ...DS4800 REFERENCE MANUAL 68 5 Figure 58 ID NET Network Connections with Common Power Branch Network...

Страница 83: ...25 PIN CABLE ELECTRICAL CONNECTIONS 69 5 Figure 59 ID NET Network Connections with Common Power Star Network...

Страница 84: ...relative to the aux interface baud rate data bits etc as well as particular communication modes such as LOCAL ECHO can be defined using the Genius utility program or Genius based Host Mode Programmin...

Страница 85: ...ource External Trigger 18 I1A External Trigger A polarity insensitive 19 I1B External Trigger B polarity insensitive 7 GND Power Reference External Trigger The External Trigger input is used in the On...

Страница 86: ...NAL TRIGGER DS4800 Signal 18 19 9 7 Ground V VCC Vdc GND I1A I1B Figure 63 NPN External Trigger using DS4800 power EXTERNAL TRIGGER INPUT CONNECTIONS USING EXTERNAL POWER DS4800 EXTERNAL TRIGGER Vext...

Страница 87: ...6 10 9 7 Ground V Signal VCC Vdc GND I2A I2B Figure 66 PNP Input 2 Using DS4800 Power INPUT DEVICE DS4800 Signal 6 10 9 7 Ground V VCC Vdc GND I2A I2B Figure 67 NPN Input 2 Using DS4800 Power INPUT 2...

Страница 88: ...Help file 5 6 OUTPUTS Two general purpose outputs are available The following pins are present on the 25 pin connector of the scanner 25 pin Name Function 9 Vdc Power Source Outputs 8 O1 Output 1 22 O...

Страница 89: ...o their own manual RS232 PC side connections 1 5 9 6 9 pin male connector 13 25 14 1 25 pin male connector Pin Name Pin Name 2 RX 3 RX 3 TX 2 TX 5 GND 7 GND 7 RTS 4 RTS 8 CTS 5 CTS How To Build A Simp...

Страница 90: ...s transmitted to the Host on the main serial interface A Genius based Host Mode programming can be accomplished either through the main interface or the Auxiliary interface In Local Echo communication...

Страница 91: ...ram or Genius based Host Mode programming In Local Echo communication mode data is transmitted on the RS232 auxiliary interface independently from the Fieldbus interface selection When On Line Operati...

Страница 92: ...the scanner is activated by an External Trigger photoelectric sensor when the object enters its reading zone Applications can be implemented to connect a device such as a hand held reader to the Auxil...

Страница 93: ...code reading capability Each DS4800 transmits its own messages plus any messages received by its Auxiliary interface onto the ID NET interface The Master passes all messages to the Host When On Line...

Страница 94: ...d to the Host on the RS232 RS485 main serial interface For a Master Slave Synchronized layout the External Trigger signal is unique to the system there is a single reading phase and a single message f...

Страница 95: ...al Echo communication mode to control any single scanner visualize collected data or to configure it using the Genius utility or the Genius based Host Mode programming procedure The ID NET termination...

Страница 96: ...T terminator into the last QL in the network ID NET on the QL500 is internally terminated Slave Nodes CBL 1480 xx CAB PW EXT CBL 1480 xx QL500 Master QL100 ID NET Host QL100 3 1 4 PS Power CBX500 w BM...

Страница 97: ...r internal CBX500 9 pin connector using the Genius configuration program or Genius based Host Mode programming Configuration can also be accomplished in Genius directly through the Ethernet network In...

Страница 98: ...al CBX500 9 pin connector using the Genius configuration program or Genius based Host Mode programming Figure 81 ID NET Fieldbus M S Synchronized Layout Figure 82 ID NET Fieldbus M S Multidata Fieldbu...

Страница 99: ...main interface All messages will be passed through this chain to the Master The Master scanner is connected to the Host on the RS232 RS485 main serial interface There is a single reading phase and a s...

Страница 100: ...erface of the slave scanners can be used in Local Echo communication mode to control any single scanner visualize collected data or to configure it using the Genius utility or Genius based Host Mode p...

Страница 101: ...tial scans on the label obtained using the motion of the label itself the scanner is able to reconstruct the barcode A typical set of partial scans is shown in the figure below Code Direction Figure 8...

Страница 102: ...still possible Laser Beam tilt angle 0 to max Figure 88 Tilt Angle The decoder will be able to read the label with a tilt angle between max and max as shown in the following figure Conveyor Laser Bea...

Страница 103: ...7 40 43 46 49 21 24 26 28 30 33 Ratio 3 1 Table 1 Code 39 Minimum Code Height for ACR4 Reading mm 45 max 30 max Conveyor Speed m s 0 5 1 1 5 2 2 5 3 0 5 1 1 5 2 2 5 3 0 25 11 14 16 19 22 25 8 10 12 14...

Страница 104: ...A Minimum Code Height for ACR4 Reading mm 45 max 30 max Conveyor Speed m s 0 5 1 1 5 2 2 5 3 0 5 1 1 5 2 2 5 3 0 25 9 12 15 18 21 23 7 9 11 13 16 18 0 30 10 13 16 19 22 24 7 9 12 14 16 18 0 33 11 14 1...

Страница 105: ...sure a successful read 7 2 1 Step Ladder Mode If scanning is perpendicular to the code motion direction Figure 90 the number of effective scans performed by the reader is given by the following formul...

Страница 106: ...effective scans FW reading field width in mm LW label width in mm LS label movement speed in mm s SS scans per second Figure 91 Picket Fence Scanning Mode For example for a 60 mm wide code moving in...

Страница 107: ...cm 37 4 in on 0 50 mm 20 mils codes 1005 Subzero Models Focus Reading Distance F 30 Near 22 cm 8 7 in 45 cm 17 7 in on 0 50 mm 20 mils codes F 40 Medium 28 cm 11 in 65 cm 25 6 in on 0 50 mm 20 mils co...

Страница 108: ...mm 20 mils 0 30 mm 12 mils 0 20 mm 8 mils NOTE 0 0 is the center of the laser beam output window CONDITIONS Code Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 0 to 30 Scan Speed 800 scans s...

Страница 109: ...mm 12 mils NOTE 0 0 is the center of the laser beam output window CONDITIONS Code Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 0 to 30 Scan Speed 800 scans sec Reading Condition Standard R...

Страница 110: ...0 mm 20 mils NOTE 0 0 is the center of the laser beam output window CONDITIONS Code Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 0 to 30 Scan Speed 800 scans sec Reading Condition Standard...

Страница 111: ...s 0 20 mm 8 mils 0 38 mm 15 mils NOTE 0 0 is the center of the laser beam output window CONDITIONS Code Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 0 to 30 Scan Speed 800 scans sec Readin...

Страница 112: ...30 mm 12 mils NOTE 0 0 is the center of the laser beam output window CONDITIONS Code Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 0 to 30 Scan Speed 800 scans sec Reading Condition Standar...

Страница 113: ...m 20 mils NOTE 0 0 is the center of the laser beam output window CONDITIONS Code Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 0 to 30 Scan Speed 800 scans sec Reading Condition Standard Re...

Страница 114: ...0 30 mm 12 mils 0 20 mm 8 mils NOTE 0 0 is the center of the laser beam output window CONDITIONS Code Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 0 to 30 Scan Speed 800 scans sec Reading...

Страница 115: ...mm 12 mils NOTE 0 0 is the center of the laser beam output window CONDITIONS Code Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 0 to 30 Scan Speed 800 scans sec Reading Condition Standard...

Страница 116: ...50 mm 20 mils NOTE 0 0 is the center of the laser beam output window CONDITIONS Code Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 0 to 30 Scan Speed 800 scans sec Reading Condition Standar...

Страница 117: ...mm 8 mils 0 38 mm 15 mils NOTE 0 0 is the center of the laser beam output window CONDITIONS Code Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 0 to 30 Scan Speed 800 scans sec Reading Condi...

Страница 118: ...30 mm 12 mils NOTE 0 0 is the center of the laser beam output window CONDITIONS Code Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 0 to 30 Scan Speed 800 scans sec Reading Condition Standa...

Страница 119: ...m 20 mils NOTE 0 0 is the center of the laser beam output window CONDITIONS Code Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 0 to 30 Scan Speed 800 scans sec Reading Condition Standard Re...

Страница 120: ...the reader Dust dirt etc on the window may alter the reading performance Repeat the operation frequently in particularly dirty environments Use soft material and alcohol to clean the window and avoid...

Страница 121: ...can refer to the Genius program help files Either connect the device and select the parameter you re interested in by pressing the F1 key or select Help Parameters Help 2K_4K Software Configuration Pa...

Страница 122: ...ode branch and check if Serial On Line is selected in the On Line Options Are the Start Stop characters correctly assigned Is the serial trigger source correctly connected and configured On line Mode...

Страница 123: ...e is not transmitting anything to the host Is the serial cable connected Is the correct wiring respected Are serial host settings equivalent to the serial device setting If using CBX be sure the RS485...

Страница 124: ...g Frequency OM models 0 2 to 20 Hz 5 Hz max 40 20 Hz max 10 Maximum Reading Distance Maximum Resolution See reading diagrams ENVIRONMENTAL FEATURES STD and OM Subzero Operating Temperature Note 2 0 to...

Страница 125: ...Terminators Up to 128 byte header string Up to 128 byte terminator string Operating Modes On Line Serial On Line Verifier Automatic Continuous Test Configuration Methods X PRESS Functions Genius utili...

Страница 126: ...governing acceptable limitations on electronic radiation from laser devices Datalogic devices are in compliance with the CDRH regulations Code Positioning Variation in code placement that affects the...

Страница 127: ...ions each of which contains terminal devices See RS485 Parameter A value that you specify to a program Typically parameters are set to configure a device to have particular operating characteristics P...

Страница 128: ...cal orientation may apply to single character line or entire encoded item See pars 3 2 1 and 3 3 Step Ladder Orientation When the barcode s bars are positioned horizontally on the product causing them...

Страница 129: ...32 L Laser Safety vii LEDs 19 Linear Code Reading 91 M Main Serial Interface 42 60 Mechanical Installation 33 Model Description 30 Mounting DS4800 36 Multiplexer Layout 86 O Oscillating Mirror Models...

Страница 130: ...2004 108 EC EMC Directive ______________________________________________ This Declaration is based upon compliance of the products to the following standards EN 55022 CLASS A ITE DECEMBER 2010 INFORMA...

Страница 131: ...uropean Council Directives listed below 2004 108 EC EMC Directive ______________________________________________ This Declaration is based upon compliance of the products to the following standards EN...

Страница 132: ...below 2004 108 EC EMC Directive ______________________________________________ This Declaration is based upon compliance of the products to the following standards EN 55022 CLASS A ITE DECEMBER 2010...

Страница 133: ...www automation datalogic com...

Отзывы: