background image

TABLE 2—NON-PROGRAMMABLE -C THERMOSTAT QUICK REFERENCE

THERMOSTAT OUTPUT

TSTAT Model

Outdoor Unit

Option 5

24v
Hot

Common

Fan

Heat

Stage 1

Heat

Stage 2

Heat

Stage 3

Cool

Stage 1

Cool

Stage 2

Reversing Valve

AC01-C

AC

N/A

R

C

G

W/W1

N/A

N/A

Y/Y2

N/A

N/A

HP01-C

HP

OFF

R

C

G

Y/Y2

W/W1

N/A

Y/Y2

N/A

O/W2/B

HP01-C

AC

ON

R

C

G

W/W1

O/W2/B

N/A

Y/Y2

N/A

N/A

2S01-C

2-Speed AC

ON

R

C

G

W/W1

O/W2/B

N/A

Y1

Y/Y2

N/A

2S01-C

2-Speed HP

OFF

R

C

G

Y1

Y/Y2

W/W1

Y1

Y/Y2

O/W2/B

Model Numbers: TSTATBBNAC01-C, TSTATBBNHP01-C, TSTATBBN2S01-C
Note: AC = Air Conditioner, HP = Heat Pump, 2S = 2-Speed, N/A = Not Applicable

Fig 4—Single-Speed Air Conditioner

with Typical Fan Coil

24 VAC HOT

24 VAC COMM

COOL STAGE 1

R

C

G

W/W1

Y/Y2

R

C

C

Y

MODEL AC 01-C

THERMOSTAT

TYPICAL

FAN COIL

SINGLE-SPEED

AIR CONDITIONER

See notes 

6

, 10 and 11

Y

G

*

W2

E

W3

HEAT STAGE 1

FAN

A98453

Fig. 2—Single-Speed Air Conditioner

with Single-Stage Furnace

A04006

24 VAC HOT

24 VAC COMM

HEAT STAGE 1

COOL STAGE 1

FAN

R

C

G

W/W1

Y/Y2

R

C

C

MODEL AC 01-C

THERMOSTAT

SINGLE-STAGE

FURNACE

SINGLE-SPEED

AIR CONDITIONER

G

W

Y

Y

HUM

See note 11

Fig. 5—Single-Speed Air Conditioner

with 2-Stage or Variable-Speed Furnace

A04008

24 VAC HOT

24 VAC COMM

HEAT STAGE 1

COOL STAGE 1

FAN

R

C

G

W/W1

Y/Y2

R

C

W2

C

Y

MODEL HP 01-C

THERMOSTAT

TWO-STAGE OR

VARIABLE-SPEED

FURNACE

SINGLE-SPEED

AIR CONDITIONER

See notes 2, 3, 4 and 11

W/W1

Y/Y2

G

HEAT STAGE 2

N/A

N/A

OUTDOOR

SENSOR

CONNECTION

Y1

B

S1

S2

O/W2/B

HUM

Y1

Fig. 3—Single-Speed Air Conditioner

with 2-Stage or Variable-Speed Furnace

A04007

24 VAC HOT

24 VAC COMM

HEAT STAGE 1

COOL STAGE 1

FAN

R

C

G

W/W1

Y/Y2

R

C

C

MODEL AC 01-C

THERMOSTAT

TWO-STAGE OR

VARIABLE-SPEED

FURNACE

SINGLE-SPEED

AIR CONDITIONER

See note 1 and 11

G

Y

W/W1

Y/Y2

W2

HUM

Y1

—6—

Содержание TSTATBBN2S01-C

Страница 1: ...lication Models are AC 1 stage cool 1 stage heat for AC systems only HP 1 stage cool 2 stage heat for either HP or AC with 2 stage heat 2S 2 stage cool 2 stage heat for 2 speed AC systems or 2 stage c...

Страница 2: ...on page 11 for explanation IV SET THERMOSTAT CONFIGURATION Configuration options are intended to be selected at installation and are normally not modified by the home owner These options are not disc...

Страница 3: ...D Option 04 G Fan On With W W1 Output This selection determines whether the G fan output is to be ON or OFF when any W furnace or strip heat output is ON Most furnaces and fan coils manage their own b...

Страница 4: ...ween 5 and 5 Factory default is 0 This adjusted value will be used as actual temperature for both display and control action For example if 2 is selected 72 F actual will read 74 F If setpoint is 72 t...

Страница 5: ...ler test will be initiated by pressing the fan button for 20 seconds 15 seconds will enter installer setup InS will appear on the screen and the SERVICE icon will be illuminated In installer test mode...

Страница 6: ...R CONDITIONER See notes 6 10 and 11 Y G W2 E W3 HEAT STAGE 1 FAN A98453 Fig 2 Single Speed Air Conditioner with Single Stage Furnace A04006 24 VAC HOT 24 VAC COMM HEAT STAGE 1 COOL STAGE 1 FAN R C G W...

Страница 7: ...ED AIR CONDITIONER See notes 2 4 6 10 and 11 Y G O W2 B W2 E W3 A98455 Fig 9 Two Speed Air Conditioner with 2 Stage or Variable Speed Furnace A04010 24 VAC HOT 24 VAC COMM HEAT STAGE 1 COOL STAGE 2 FA...

Страница 8: ...2 4 5 6 8 10 and 11 Y G O W2 B W2 R Y2 E W3 A98459 Fig 13 Single Speed Air Conditioner with Variable Speed FK4D FV 40FK Fan Coil A98464 24 VAC HOT HEAT STAGE 1 24 VAC COMM COOL STAGE 1 FAN R G W W1 Y...

Страница 9: ...n Coil A98466 24 VAC HOT 24 VAC COMM FAN COOL HEAT STAGE 1 HEAT STAGE 2 R Y Y2 R C C C R MODEL HP THERMOSTAT EASY SELECT TERMINAL BOARD SINGLE SPEED HEAT PUMP J1 JUMPER J2 JUMPER See notes 7 8 and 11...

Страница 10: ...eat Refer to indoor equipment Installation Instructions for proper setup 5 Refer to outdoor equipment Installation Instructions for latent kit requirements if any 6 Terminals marked with may not be pr...

Страница 11: ...s the model configuration via the following 2 digit code AC 1 speed air conditioner HP 1 speed heat pump A2 2 speed air conditioner H2 2 speed heat pump ERROR CODES If the thermostat cannot properly r...

Страница 12: ...AC Configuration 6 Cooling Lockout Off or On factory default Off 7 Zoning Selection Off or On factory default Off 8 Auxiliary Heat Lockout Off or 5 55 F factory default Off 9 N A 10 O Reversing Valve...

Отзывы: