Bryant HRVBBLHU Скачать руководство пользователя страница 1

NOTE:

Read the entire instruction manual before starting the

installation.

This symbol

indicates a change since the last issue.

Index

Page

SAFETY CONSIDERATIONS .....................................................2
INTRODUCTION ..........................................................................2
LOCATION....................................................................................2

Inspect Equipment ....................................................................2
Select Location..........................................................................2

UNIT INSTALLATION.............................................................2-3

Mount Unit................................................................................2
Independent System Application..............................................2
Forced-Air Application.............................................................3
Connect Ducts to HRV.............................................................3
Condensate Drain......................................................................3
Locate and Install Exterior Hoods ........................................3-4

COMPONENT DESCRIPTION ....................................................5
WALL CONTROL ........................................................................6

Location.....................................................................................6
Basic Control Operation ...........................................................6
Standard Control Operation......................................................6
Automatic Control Operation ...................................................6
Wiring........................................................................................7
Humidity Selector .....................................................................7

ELECTRICAL CONNECTIONS...............................................7-8

115-vac Wiring .........................................................................7
12-vdc Wiring ...........................................................................7

ACCESSORIES..............................................................................8

Interlock Relay..........................................................................8
20 Minute Timer.......................................................................8
60 Minute Adjustable Timer ....................................................8

BALANCING HRV................................................................10-11

Balancing Dampers.................................................................10
Flow Collars............................................................................11

VENTILATION EVALUATION ................................................13

Method 1 .................................................................................13
Method 2 .................................................................................13

CONTROL BOARD OPERATION ............................................13

Board Function........................................................................13
Defrost.....................................................................................13
Off and Intermittent/Off Mode...............................................13
High-Speed Air Exchange ......................................................13
Low-Speed Air Exchange.......................................................13

CARE AND MAINTENANCE...................................................14

Door.........................................................................................14
Filter ........................................................................................14
Blower Motor and Wheel.......................................................14
Cleaning the Core ...................................................................14

TROUBLESHOOTING ..........................................................14-17

Wall Control............................................................................14
Control Board..........................................................................14
Blower Motor..........................................................................14
Blower Speed Selection..........................................................15
Defrost.....................................................................................16
Control Module Jumpers ........................................................16
Error Signaling ..................................................................16-17

WIRING DIAGRAMS ...........................................................18-19

DIMENSIONAL DRAWINGS ..............................................20-22

Fig. 1—HRVBBLHU Conventional Unit

A99271

Fig. 2—HRVBBSVU Compact Unit

A92268

Fig. 3—HRVBBLVU High Efficiency Unit

A92377

installation, start-up,
and operating instructions

HEAT RECOVERY
VENTILATOR

Cancels:

II HRV-71-2

II HRV-71-3

6-05

HRVBBLHU,
HRVBBSVU,

HRVBBLVU

—1—

Содержание HRVBBLHU

Страница 1: ...8 20 Minute Timer 8 60 Minute Adjustable Timer 8 BALANCING HRV 10 11 Balancing Dampers 10 Flow Collars 11 VENTILATION EVALUATION 13 Method 1 13 Method 2 13 CONTROL BOARD OPERATION 13 Board Function 1...

Страница 2: ...damage unit Remove all packaging and inspect unit for damage Remove parts bag from inside unit File claim with shipping company if shipment is damaged or incom plete Check to make sure HRV unit match...

Страница 3: ...when connecting ducts to return air duct system This should eliminate transmission of noise or vibration from unit to main duct system NOTE Balancing dampers should be installed in stale air exhaust a...

Страница 4: ...FRESH AIR EXHAUST TO OUTSIDE NOTE SUPPLY EXHAUST DUCTS TO HAVE BALANCING DAMPERS ON COLD SIDES SEE STEP 4 CONNECT DUCTS TO HRV 6 FEET FURNACE 6 IN 6 IN REAR INLET HOOD 6 FEET EXHAUST HOOD 18 IN HRV 1...

Страница 5: ...return air duct system 2 Fresh air intake connected to outdoor air inlet hood 3 Exhaust air connected to outdoor air exhaust hood 4 Dampers are used to control air exchange with outdoor air during def...

Страница 6: ...tion LED remains on When there is a call for dehumidification exchange LED is on and HRV exchanges air with outside When dehumidistat is satisfied HRV dampers close which recirculates indoor air The e...

Страница 7: ...POSITION OPERATION DAMPER POSITION FAN SPEED ON LED AIR EXCHANGE LED Off Any Off Closed to outside Off Off Off Low Satisfied Off Open to outside Low On Off Call for dehumidification Air exchange with...

Страница 8: ...as bathrooms or kitchen where high speed exhaust operation is needed for a short period of time NOTE The 20 minute timer will not function properly unless HRV wall control is applied and working corr...

Страница 9: ...Y Y 3 2 1 1 4 7 2 5 8 3 6 9 CONDENSING UNIT 9 PIN AMP PLUG 120V FROM HRV Fig 14 Push Button Timer Wiring Layout A98386 3 4 5 I OC OL YELLOW BLACK RED ELECTRONIC CONTROL BOARD BACK OF PUSH BUTTON SWIT...

Страница 10: ...ryer exhaust fume hoods bath or roof fans should be in operation The forced air furnace if used for circulation should be operating in continuous fan mode for normal operating speed I BALANCING DAMPER...

Страница 11: ...flow collar to convert static pressure into airflow Once HRV is balanced and dampers are adjusted to equalize airflow use tape or drive screws to prevent damper blades from moving Remove flow collars...

Страница 12: ...U Airflow During Air Exchange A92382 STALE AIR FROM BUILDING FRESH AIR TO BUILDING FRESH AIR FROM OUTSIDE STALE AIR TO OUTSIDE Fig 25 HRVBBLVU Airflow During Recirculation and Defrost A92385 STALE AIR...

Страница 13: ...ced or you encounter unusual start up operation check jumpers to make sure they are located properly See Fig 27 and 28 II DEFROST The HRV continually monitors the outside air temperature If the outsid...

Страница 14: ...wer to system There may be more than 1 disconnect switch CAUTION CUT HAZARD Failure to follow this caution may result in personal injury Sheet metal parts may have sharp edges or burrs Use care and we...

Страница 15: ...y Electrical supply interrupted Check units circuit breaker Air from distribution register too cold Improper calibration of air flow Check calibration of flow rates Unit makes annoying noise Ventilati...

Страница 16: ...ule give exact configuration to HRV micro controller If there is a mistake in the jumper configura tion it can cause improper unit operation This control has a simplified jumper selection mode Jumper...

Страница 17: ...sec Check all wires to wall control particularly green wire If problem still exists test wall control with 5 ft of wire from HRV If this works change wall control module inside HRV C Reset To reset HR...

Страница 18: ...N TABLE A RELAY K5 0 1 1 0 0 0 0 MODE Intermittent Exchange Low Exchange High Circulation low Circulation high Defrost Cycle Off 0 Relay coil is de energized 1 Relay coil is energized NS Not supported...

Страница 19: ...HRVBBLVU1330 4 IF ANY OF THE ORIGINAL WIRE AS SUPPLIED MUST BE REPLACED USE THE SAME OR EQUIVALENT WIRE 5 FACTORY SET WIRING FOR BLOWER SPEED SELECTION IS HIGH AND LOW MEDIUM SPEED CAN BE SELECTED IN...

Страница 20: ...HRVBBLHU1250 19 483 5 13 16 147 7 5 1 16 128 1 14 1 2 368 9 11 3 16 254 0 5 13 16 401 6 9 5 16 236 6 A99263 A 20 508 0 B 15 381 0 G 4 3 4 120 6 D C 30 1 4 768 3 2 5 16 58 7 18 1 8 460 4 16 7 8 428 6 N...

Страница 21: ...0 19 5 16 490 6 14 9 16 369 9 16 15 16 430 2 6 7 8 174 6 19 15 16 506 2 A98003 5 3 4 146 0 D 2 27 685 8 22 1 16 560 4 1 25 4 2 PLCS 15 11 16 398 5 E 3 1 4 1 15 16 23 8 3 3 16 81 0 4 9 16 115 9 F DIA 2...

Страница 22: ...3 16 55 6 2 PLCS 12 3 4 323 9 23 15 16 608 0 43 1092 2 19 1 16 484 2 8 3 16 208 0 7 3 16 182 6 DRAIN 11 16 DIA 17 5 2 PLCS 24 1 16 611 2 1 1 2 38 1 2 PLCS 22 3 8 568 3 41 1041 4 1 25 4 2 PLCS 15 1 2...

Страница 23: ...oduct theory and skills programs is available using popular video based formats and materials All include video and or slides plus companion book Classroom ServiceTraining plus hands on the products i...

Страница 24: ...2005 Bryant Heating Cooling Systems 7310 W Morris St Indianapolis IN 46231 24 Printed in U S A hrv713 Catalog No II HRV 71 3...