INSTALLATION

Step 1 —

Check Perfect Air Air Purifier Components

PERSONAL INJURY HAZARD

Failure to follow this caution may result in personal injury.
Sheet metal parts may have sharp edges or burrs. Use care and

wear appropriate protective clothing and gloves when

handling parts.

CAUTION

!

Carefully remove all items from the box.

Step 2 —

Identify Mounting Location

a. Identify a mounting orientation for the Perfect Air Air Purifier

in the return air duct (see Fig. 4).

b. Ensure airflow direction through the Perfect Air Air Purifier

matches the arrows on the face of the air purifier cartridge.
The Perfect Air Air Purifier or door can be rotated 180

_

to

accommodate the cabinet orientation.

c. The location of the Perfect Air Air Purifier should be readily

accessible. Enough room should be provided for periodic re-

placement of the air purifier cartridges.

Step 3 —

Mount Cabinet

a. Turn off power to the heating and cooling system.

b. Remove the existing fan coil filter and discard. Excessive sys-

tem static pressure may result if the Perfect Air Air Purifier is

used with other filtration devices.

c. Remove the air purifier cartridge and enhancement module

from the Perfect Air Air Purifier cabinet.

d. Position the cabinet between the fan coil and return air duct

(see Fig. 4 and 5). A transition duct may be required.

NOTE

: The fan coil cabinet screws holding the filter rack should

be used to attach the air purifier cabinet.

a. Gasket tape between the fan coil and the air purifier cabinet is

already factory installed.

b. Mounting holes are provided for fan coil attachment.

c. Use return duct adapters provided to attach return ductwork

(See Fig. 6).

d. Seal seams with tape or caulking after the Perfect Air Air Puri-

fier cabinet has been secured.

A06517

Downflow

A06371

Horizontal

Airflow

A06374

Upflow

Airflow

Airflow

Fig. 4 -- Perfect Air Air Purifier Cabinet Orientation

Return Duct

Adapters (x4)

A06389

Mounting Cabinet Vertical

Return Duct

Adapters (x4)

A06388

Mounting Cabinet Horizontal

Fig. 5 -- Mounting Perfect Air Air Purifier Cabinet For Fan Coils

GAP

A

B

Содержание GAPAB

Страница 1: ...La Perfect Air Air Purifier certification CSA vise uniquement les risques de choc electrique et A06367 Fig 1 GAPAB Unit SAFETY CONSIDERATIONS Improper installation adjustment alteration service maintenance or use can cause explosion fire electrical shock or other conditions which may cause death personal injury or property damage Consult a qualified installer service agency or your distributor or ...

Страница 2: ...t recommended and a standard disposable furnace filter should be mounted between the humidifier and the air purifier to trap hard water salt deposits and water droplets Transitions If the return air duct or fan coil openings do not fit the Perfect Air Air Purifier cabinet openings gradual transitions are recommended to reduce air turbulence and maximize efficiency No more than 20 degrees about 4 i...

Страница 3: ...stem b Remove the existing fan coil filter and discard Excessive sys tem static pressure may result if the Perfect Air Air Purifier is used with other filtration devices c Remove the air purifier cartridge and enhancement module from the Perfect Air Air Purifier cabinet d Position the cabinet between the fan coil and return air duct see Fig 4 and 5 A transition duct may be required NOTE The fan co...

Страница 4: ...e power has been removed from the heating and cooling system b Turn the Perfect Air Air Purifier power switch off c Connect the power cord and the flow sensor cord to the power supply connector and the flow sensor connector see Fig 7 and Fig 8 A06414 Fig 7 Flow Sensor Cable Installed A06413 Fig 8 Power Cord Installed NOTE The power cord can be routed through the opposite side of the cabinet Zip ti...

Страница 5: ...ranty CAUTION AIR FLOW SENSOR CABLE OR AIR FLOW SENSOR BYPASS PLUG MUST BE CONNECTED TO THE POWER SUPPLY IN ORDER TO ACTIVATE THE AIR PURIFIER NOTICE A06670 Fig 9 Airflow Sensor Bypass Plug Installed TO FAN COIL FIELD POWER CONNECTION FUSED POWER CONNECTOR LEADS FROM INSTALLATION COMPONENTS IN BAG ATTACHED TO POWER CORD AIR PURIFIER POWER CORD TO FAN COIL FIELD POWER CONNECTION TO L2 FIELD POWER S...

Страница 6: ...s obtained when the furnace blower is set for continuous operation on the thermo stat or Perfect Air Control MAINTENANCE The Perfect Air Air Purifier is designed to require minimal maintenance Maintenance is limited to the replacement of the air purification cartridge and inspection brush cleaning of the ionization array Frequency of air purifier cartridge replacement and cleaning of the ionizatio...

Страница 7: ...ch bar with enough brush depth to hit front and back tips of the points in the ionization array Use a gentle back and forth brushing motion to clean any small accumulations from the tips of the points If desired use vacuum cleaner with brush attachment to gently vacuum the frame and components of enhancement module Step 8 Reinstall the Safety Screen Step 9 Slide in enhancement module Step 10 Recon...

Страница 8: ...Step 3 Confirm that the fan coil blower is operating Step 4 Confirm that 208 230 VAC power is provided Attach power supply connector to the air purifier when the fan coil blower is operating NOTE Even though power is supplied to the Perfect Air Air Purifier it will not turn on unless the airflow sensor senses airflow or the airflow sensor s bypass plug is inserted Step 5 Confirm that the airflow s...

Страница 9: ...imum Airflow CFM 1350 1800 2000 Efficiency Equivalent to MERV 15 Equivalent to MERV 15 Equivalent to MERV 15 Replacement Cartridge GAPCCCAR1620 GAPCCCAR2020 GAPCCCAR2420 Initial Pressure Drop in w c at maximum airflow 22 25 22 DIMENSIONS GAPABXBB1620 GAPABXBB2020 GAPABXBB2420 A 18 1 2 22 25 1 2 B 15 1 8 18 5 8 22 1 8 C 13 1 8 13 1 8 13 1 8 D 17 5 8 21 1 8 24 5 8 E 19 3 4 19 3 4 19 3 4 F 22 1 4 22 ...

Страница 10: ...10 GAPAB ...

Страница 11: ...s and exclusions listed below and on the reverse if any of this document OWNER OCCUPIED RESIDENTIAL APPLICATIONS This warranty is to the original purchasing owner and is transferable only to the extent and as stated in the Warranty Conditions and below The warranty period in years depending on the part and the claimant is as shown in the chart below Limited Warranty Years Product Original Owner Su...

Страница 12: ...TIONS ON HOW LONG AN IMPLIED WARRANTY OR CONDITION LASTS SO THE ABOVE MAY NOT APPLY TO YOU THE EXPRESS WARRANTIES MADE IN THIS WARRANTY ARE EXCLUSIVE AND MAY NOT BE ALTERED ENLARGED OR CHANGED BY ANY DISTRIBUTOR DEALER OR OTHER PERSON WHATSOEVER THIS WARRANTY DOES NOT COVER 1 Labor or other costs incurred for diagnosing repairing removing installing shipping servicing or handling of either defecti...

Отзывы: