Sizes:
014, 017, 021, 024
Installation Instructions
FNCCAB
High Efficiency Filtration System
For Fan Coils
C04032
Fig. 1 -- FNCCAB High Efficiency Air Filtration System
NOTE
: Read the entire instruction manual before starting the
installation.
SAFETY CONSIDERATIONS
Improper installation, adjustment, alteration, service, maintenance,
or use can cause explosion, fire, electrical shock, or other
conditions which may cause death, personal injury, or property
damage. Consult a qualified installer, service agency, or your
distributor or branch for information or assistance. The qualified
installer or agency must use factory--authorized kits or accessories
when modifying this product. Refer to the individual instructions
packaged with the kits or accessories when installing.
Follow all safety codes. Wear safety glasses, protective clothing,
and work gloves. Use quenching cloth for brazing operations.
Have fire extinguisher available. Read these instructions
thoroughly and follow all warnings or cautions included in
literature and attached to the unit.. Consult local building codes
and current editions of the National Electrical Code ( NEC ) NFPA
70. In Canada, refer to current editions of the Canadian electrical
code CSA 22.1.
Recognize safety information. This is the safety--alert symbol
.
When you see this symbol on the furnace and in instructions or
manuals, be alert to the potential for personal injury. Understand
the signal words
DANGER
,
WARNING
,
CAUTION
and
NOTE
.
The words
DANGER
,
WARNING
, and
CAUTION
are used with
the safety alert symbol.
DANGER
identifies the most serious
hazards which
will
result in severe personal injury or death.
WARNING
signifies a hazard which
could
result in personal
injury or death.
CAUTION
is used to identify unsafe practices
which
may
result in minor personal injury or product and property
damage.
NOTE
is used to highlight suggestions which
will
result
in enhanced installation, reliability, or operation.
INTRODUCTION
These instructions cover the installation, operation and
maintenance of FNCCAB High Efficiency Air Filtration System.
Become familiar with the components listed in Table 1. See Fig. 2.
Table 1 – FNCCAB Major Components
COMPONENT
DESCRIPTION
1
Cabinet
2
Filter
3
Access Handle
4
Access Door
5
Door Latch Hardware
6
Door Alignment Table
DESCRIPTION AND USAGE
UNIT OPERATION AND SAFETY HAZARD
Failure to follow this caution may result in personal injury
and/or damage to the equipment.
Prior to installing this product, you should read these entire
instructions and follow all directions.
CAUTION
!
APPLICATION
This High Efficiency Air Filtration System must be used in a
forced air heating, cooling or ventilation system. This High
Efficiency Air Filtration System cleaner should be installed in the
system so that all the system air is circulated through this air
cleaner. The High Efficiency Air Filtration System will only
remove the airborne contaminants delivered to it. Maximum
performance is obtained when the system blower is set for
continuous operation.
INSTALLATION REQUIREMENTS
The location for the High Efficiency Air Filtration System is on the
return side of the fan coil next to the blower compartment. In this
location, both the blower motor and cooling coils will be kept
clean. Do not install the air cleaner in the discharge (supply) air
duct. The front of this unit must be readily accessible for periodic
inspection and replacement of filter to maintain maximum
efficiency and trouble--free operation.