background image

 

Form No. PDS FH4B.01.3

 

FAN UNIT

 

 FH4B

 

Sizes 001 thru 004

 

 

PRACTICALITY & PERFORMANCE

 

Reliability, dependability, and great value are built into the FH4B
Fan Units. The unit is compact and easy to install, with capacities
ranging from 800 to 2000 CFM. The units are the right choice if
you need versatility and affordability in a fan unit.  

These fan coil units offer an air handler for practical, no-non-
sense application and outstanding performance. The multipoise
units allow greater flexibility to meet your upflow, downflow, or
horizontal installation requirements, and offer multiple electric
entry to permit quick, hassle-free hookup (003 and 004 when
coupled with coil are upflow/downflow only). All models come
fully equipped with solid-state cooling controls. 

The FH4B, with its 3-speed motor and field-installed heater
package, provides the application versatility required for most
installations. Heater packages are available from 3- through 30-
kw, either fused or with a circuit breaker, or non-fused for 10-kw
and less.  

Содержание FAN UNIT FH4B

Страница 1: ...cation and outstanding performance The multipoise units allow greater flexibility to meet your upflow downflow or horizontal installation requirements and offer multiple electric entry to permit quick...

Страница 2: ...fused circuit breaker non fused 10 kw and down Factory supplied power plug Control board with replaceable 5 amp blade type auto fuse Foil faced high density super thick R 4 2 insulation Multiple elec...

Страница 3: ...CONFIGURATION OPERATING WEIGHT Lb In In In In SLOPE A FH4BNF001 E 42 11 16 14 5 16 12 7 16 12 5 16 175 FH4BNF002 E 49 5 8 17 5 8 15 3 4 15 5 8 192 FH4BNF003 E 49 5 8 21 1 8 19 1 4 19 1 8 106 FH4BNF004...

Страница 4: ...4 DIMENSIONS Continued A02301...

Страница 5: ...ling coil Field modified Side Return Location For Slope Coils Only POWER ENTRY OPTIONS LOW VOLT ENTRY OPTIONS FIELD MODIFIED SIDE RETURN LOCATION FOR SLOPE COIL UNITS ONLY FIELD SUPPLIED RETURN PLENUM...

Страница 6: ...4 1438 1225 1407 1190 1383 1170 1342 1141 1308 1100 1265 LOW 1001 1172 985 1147 955 1116 930 1094 908 1062 850 1024 FH4B003 HIGH 2118 2060 2202 1949 2106 1853 1989 MED 1757 2061 1745 2016 1734 1985 17...

Страница 7: ...TER KW PHASE FUSES QTY SIZE CKT BKR QTY SIZE 3 1 5 1 1 60 8 1 1 60 10 1 1 60 15 1 2 30 2 60 2 60 20 1 4 60 2 60 24 3 1 6 60 30 3 1 6 60 9 1 3 15 3 18 3 HEATER PART NO KW 240V VOLTS PHASE STAGES KW OPE...

Страница 8: ...ction Ductwork passing through unconditioned space must be insulated and covered with vapor barrier ESTIMATED SOUND POWER LEVEL dBA Estimated sound power levels have been derived using the method desc...

Страница 9: ...3 8 58 5 6 6 10 10 60 60 78 80 KFCEH3001F15 15 11 3 1 Fuse 54 2 59 9 36 2 40 0 18 1 20 0 76 3 83 4 53 8 58 5 22 7 25 0 4 4 6 6 10 10 8 8 10 10 10 10 80 90 60 60 25 25 88 89 78 80 75 76 KFCEH3101C15 15...

Страница 10: ...ed in downflow applications 4 Single Point Wiring Kit The single point wiring kit acts as a jumper between L1 and L3 lugs and between the L2 and L4 lugs This allows the installer to run 2 heavy gage h...

Страница 11: ...11 ELECTRONIC AIR CLEANER VENTILATOR PLUS ZONE PERFECT PLUS EQUIPMENT CONTROLLER HEAT PUMP HUMIDIFIER FAN COIL A02295 MATCHED SYSTEM...

Страница 12: ...scussed in this manual including Unit Familiarization Maintenance Installation Overview Operating Sequence A large selection of product theory and skills programs is available using popular video base...