3
Fig. 1 — 580J*04-07 Units Model Number Nomenclature
Note: On single phase (-J voltage code) models, the
following are not available as a factory installed option:
- Coated Coils or Cu Fin Coils
- Louvered Hail Guards
- Economizer or 2 Position Damper
- Powered 115 Volt Convenience Outlet
Model
J - Puron
®
(R-410A) Refrigerant
Unit Type
580 - Gas Heat RTU
Legacy™
Series
Packaging & 2-Speed Indoor Fan Motor
A = Standard Packaging, electro mech. controls
that require W7212 EconoMi$er
®
IV
B = LTL Packaging, electro mech. controls
that require W7212 EconoMi$er IV
C = Standard Packaging, electro mech. controls
that require W7220 EconoMi$er X
F = LTL Packaging, electro mech. controls
that require W7220 EconoMi$er X
Cooling Tons
04 - 3 tons
05 - 4 tons
06 - 5 tons
07 - 6 tons
Heat Level
Standard/Stainless Steel
072 = 72,000
115 = 115,000
125 = 125,000
150 = 150,000
Low NOx
060 = 60,000
090 = 90,000
120 = 120,000
Indoor Fan Options
0 = Direct Drive, Standard Staitc Option (04/05/06 models only)
1 = Belt Drive, Standard Static Option
2 = Belt Drive, Medium Static Option
3 = Belt Drive, High Static/ Option
Refrig. System/Gas Heat Options
A = Standard One Stage cooling models/Natural Gas Heat
B = Standard One Stage cooling models/Low NO
x
Heat
C = Standard One Stage cooling models/Stainless Steel HX Heat
G = One Stage cooling models/Alum Heat Exchanger
with Perfect Humidity™ (07 models only)
J = One Stage cooling models/Stainless Steel Exchanger
with Perfect Humidity™ (07 models only)
Coil Options For Round Tube/Plate Fin Condenser Coil Models Only
(Outdoor - Indoor - Hail Guard)
A = Al/Cu - Al/Cu
B = Precoat Al/Cu - Al/Cu
C = E-coat Al/Cu - Al/Cu
D = E-coat Al/Cu - E-coat Al/Cu
E = Cu/Cu - Al/Cu
F = Cu/Cu - Cu/Cu
M = Al/Cu -Al/Cu — Louvered Hail Guard
N = Precoat Al/Cu - Al/Cu — Louvered Hail Guard
P = E-coat Al/Cu - Al/Cu — Louvered Hail Guard
Q = E-coat Al/Cu - E-coat Al/Cu — Louvered Hail Guard
R = Cu/Cu - Al/Cu — Louvered Hail Guard
S = Cu/Cu - Cu/Cu — Louvered Hail Guard
Coil Options For All Aluminum - Novation Condenser Coil Models Only
(Outdoor - Indoor - Hail Guard)
G = Al/Al - Al/Cu
H = Al/Al - Cu/Cu
J = Al/Al - E-coat Al/Cu
K = E-coat Al/Al - Al/Cu
L = E-coat Al/Al - E-coat Al/Cu
T = Al/Al - Al/Cu — Louvered Hail Guard
U = Al/Al - Cu/Cu — Louvered Hail Guard
V = Al/Al - E-coat Al/Cu — Louvered Hail Guard
W = E-coat Al/Al - Al/Cu — Louvered Hail Guard
X = E-coat Al/Al - E-coat Al/Cu — Louvered Hail Guard
Voltage
E = 460-3-60
J = 208/230-1-60
P = 208/230-3-60
T = 575-3-60
Example:
Position:
5
8
0
J
E
0
6
A
0
7
2
A
1
B
0
A
A
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
Factory Installed Options
0A =
None
NOTE:
See the 580J 3 to 15 ton Price Pages for a
complete list of factory installed options.
Outdoor Air Options
A = None
B = Temperature Economizer, Barometric Relief,
Standard Leak (W7212 or W7220)
E = Temperature Economizer, Barometric Relief,
Standard Leak w/CO
2
, (W7212 or W7220)
H = Enthalpy Economizer, Barometric Relief,
Standard Leak, (W7212 or W7220)
L = Enthalpy Economizer,Barometric Relief,
Standard Leak w/CO
2
, (W7212 or W7220)
Q = Motorized 2 Position Damper
U = Temperature Economizer, Barometric Relief,
Ultra Low Leak, (W7220)
W = Enthalpy Economizer, Barometric Relief,
Ultra Low Leak, (W7220)
Содержание 580J*04A
Страница 4: ...4 Fig 2 Unit Dimensional Drawing ...
Страница 5: ...5 Fig 2 Unit Dimensional Drawing cont ...
Страница 21: ...21 Fig 34 580J Size 07 Unit with Perfect Humidity Dehumidification System Humidistat Wiring ...
Страница 37: ...37 Fig 43 Typical RTU Open System Control Wiring Diagram ...
Страница 38: ...38 Fig 44 Typical RTU Open System Control Wiring Diagram with Perfect Humidity ...
Страница 49: ......