background image

1

359BAV

Variable Speed Gas Furnace

Owner’s Manual

NOTE TO INSTALLER:

THIS MANUAL MUST BE LEFT

WITH THE EQUIPMENT USER.

USER:

Please read all instructions in the manual and retain all

manuals for future reference.

FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly could result in

injury, death, or property damage.
Do not store or use gasoline or other flammable vapors and

liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS

--Do not try to light any appliance.

--Do not touch any electrical switch; do not use any

phone in your building.

--Leave the building immediately.

--Immediately call your gas supplier from a neighbor’s

phone. Follow the gas supplier’s instructions.

--If you cannot reach your gas supplier, call the fire

department.

Installation and service must be performed by a qualified

installer, service agency or the gas supplier.

!

WARNING

CARBON MONOXIDE POISONING HAZARD

Failure to follow this warning could result in personal

injury and/or death.
Carbon Monoxide is invisible, odorless, and toxic! Bryant

Heating & Cooling Corporation recommends a carbon

monoxide alarm in your home, even if you do not own a

gas appliance. Locate the carbon monoxide alarm in the

living area of your home and away from gas appliances and

doorways to attached garages. Follow the alarm

manufacturer’s instruction included with the alarm.

!

WARNING

Do not use this furnace if any part has been under water. A

flood--damaged furnace is extremely dangerous. Attempts to

use the furnace can result in fire or explosion. A qualified

service agency should be contacted to inspect the furnace

and to replace all gas controls, control system parts,

electrical parts that have been wet or the furnace if deemed

necessary.

CERTIFIED

As an ENERGY STAR

®

Partner,

Bryant Heating & Cooling Sys-

tems has determined that this

product meets the ENERGY

STAR

®

guidelines for energy

efficiency.

SAFETY CONSIDERATIONS

Recognize safety information. This is the safety--alert symbol

.

When you see this symbol on the furnace and in instructions or
manuals, be alert to the potential for personal injury.
Understand the signal words:

DANGER, WARNING, and

CAUTION. DANGER identifies the most serious hazards which

will

result in severe personal injury or death. WARNING signifies

hazards which

could

result in personal injury or death. CAUTION

is used to identify unsafe practices which

may

result in minor

personal injury or product and property damage. NOTE is used to
highlight suggestions which

will

result in enhanced installation,

reliability or operation.
To minimize the possibility of serious personal injury, fire, furnace

damage, or improper operation;

carefully follow these safety

rules

:

S

Your gas furnace uses air from outside the home for combustion
and vents flue gas to the outdoors. It is not to be installed using
indoor air for combustion. The vent pipe must terminate outside
the structure and must not be obstructed in any way. The
air--intake pipe must terminate outside the structure or in a well
ventilated area that is isolated from the living space and the
garage (e.g. well ventilated attic or crawlspace). Do not block or
obstruct air openings on furnace or spaces around furnace.

S

Keep the area around your furnace clear and free of combustible
materials, gasoline, and other flammable liquids and vapors.

Содержание 359BAV

Страница 1: ...ice agency should be contacted to inspect the furnace and to replace all gas controls control system parts electrical parts that have been wet or the furnace if deemed necessary CERTIFIED As an ENERGY...

Страница 2: ...ze 5 On appliances with a draft hood check for spillage by hold ing a lighted match 2 50 8mm from the draft hood open ing Reference Fig 1 which shows a water heater draft hood Typical Gas Water Heater...

Страница 3: ...have a Fan Switch with AUTO and ON settings On AUTO the Circulating Air Blower will cycle on off with the furnace on the heating speed unless a call for cooling is initiated Blower speed will correspo...

Страница 4: ...ors 8 Turn ON all electrical power to the furnace 9 Set the thermostat to the desired temperature and the System Select Switch to HEAT The furnace will activate an igniter which lights the main burner...

Страница 5: ...cleaned or replaced as required There are many types of filters that are commonly used Washable filters constructed of aluminum mesh foam or reinforced fibers may be cleaned by soaking in mild deterge...

Страница 6: ...ace External Filter Rack A plastic end cap is inserted in the filter rack after the filter is installed The end cap keeps air from escaping around the open end of the filter rack See Fig 4 for removal...

Страница 7: ...rs 800 900 20 x 25 508 x 635 1 Req 14 x 25 356 x 635 1 Req 1100 1300 14 x 25 356 x 635 2 Req 14 x 25 356 x 635 1 Req 1300 1500 16 x 18 406 x 457 2 Req 16 x 18 406 x 457 1 Req 1500 1700 20 x 25 508 x 6...

Страница 8: ...Systems TO OBTAIN INFORMATION ON PARTS Consult your installing dealer or classified section of your local telephone directory under the Heating Equipment or Air Conditioning Contractors Systems headin...

Отзывы: