A
BRYANT DENTAL
PRODUCT
Страница 1: ...A BRYANT DENTAL PRODUCT ...
Страница 2: ... 44 0 1932 320064 44 0 7990 113723 ...
Страница 3: ...cision printing combined with the latest AI technology in customer service allows us to deliver to you products previously thought impossible Smart dentistry in a whole new light Wireless Light System Contents 06 Ignis Instructions 10 Charging 11 Technical 12 Safety Instructions 14 Servicing and Troubleshooting 15 Disposal Notice 15 Warranty www bryant dental 03 ...
Страница 4: ...HINGELESS Rotating lens filter design UNIFORM BEAM PATTERN Edge edge conformity for maximum clarity 44 0 1932 320064 44 0 7990 113723 ...
Страница 5: ...s than three seconds NO FIDDLING WITH SCREWS OR WIRES Cool Blue Indicator light for battery management INDICATION Head strap is a specialised silicone rubber which is disinfectable and non sticky SPECIALISED SILICONE RUBBER PLEASE DO NOT USE if you have a silicone rubber allergy www bryant dental 05 ...
Страница 6: ...signed to be used by qualified dental professionals including but not limited to dentists and dental hygienists as well as medical doctors and or professionals Ignis must be used with the bracket provided which is specific to your frames What s included Ignis LED with integrated headstrap X1 Dichroic Wavelength Filter X2 Ignis Batteries X1 Battery Charging Plate X1 Ignis USB Wall Plug country spec...
Страница 7: ...es to the OFF position shown below Attaching the battery switch Attaching O Rings Neodymium magnet powered battery switch Base plate Slide the O Rings down the right Loupe arm see O Ring positioning shown above to hold power cable Then slide the head strap over the memory metal earpieces shown below Head strap ...
Страница 8: ...hen switched ON to calculate optimum output Select power modes 44 0 1932 320064 44 0 7990 113723 IMPORTANT For safety reasons to operate in high power mode the battery must first be switched to regular and then to high Blue indicator lights are activated when device is ON When indicator light does not show any bars the battery is near depletion and requires charging See page 10 for charging ...
Страница 9: ...ight This design prevents the filter accidentally rotating into place Selecting the lens filter This filter cuts out the curing wavelengths of light to prevent composite setting with a bright yellow tint rather than dark orange This allows fine aesthetic work with the light on TO AVOID DAMAGE Please do not lift the lens filter upwards Rotate only Dos and Don ts ROTATE LIFT 5 ...
Страница 10: ...ry from the head strap plate Combine your USB mains adaptor and battery charging plate together shown below Attach battery to battery charging plate Aligning the grooves on the top to activate the charging sequence shown above Once a FULL bar appears and stops flashing the battery is fully charged Battery position Do not expose batteries to naked flame Neodymium magnet powered battery switch USB m...
Страница 11: ...mens Overall Unit Weight 32g LED Weight 9g IPX IPX0 0 Rated The charge circuit is protected by a MCP73831 charge control chip This has current limiting protection and over temperature protection along with reverse discharge protection Adverse Reactions None Known Storage Temperature 0 35ºC Charging Temperature 10 35ºC Operating Temperatures 10 40ºC Operating Power DC3 7V 700mA Charger Input AC100 ...
Страница 12: ...he unit to overheat Do not leave the batteries on exposed skin Do not charge unattended or leave in environments exceeding 40 C Do not attach multiple batteries together Batteries should be stored in a cool dry place If batteries behave abnormally immediately contact Bryant Dental Take care when attaching battery to base plate to avoid trapping your hair Take care not to touch the LED during use a...
Страница 13: ...VE OR CHEMICLAVE DO NOT USE GLUTARALDEHYDE OR IDOPHOR DO NOT USE A CLEANER WITH ALCOHOL CONCENTRATION GREATER THAN 70 You may disinfect using a low alcohol disinfectant such as Formula42 or soap and water Please follow the instructions on the disinfectant product to ensure satisfactory sanitisation Take care to ensure the ventilation gap around the LED is thoroughly cleaned along with all other su...
Страница 14: ...decrease as in most Lithium Ion batteries If the battery is under 1 year old and not lasting a full session please ensure it is being used in regular mode not high power mode If still an issue please contact Bryant Dental and cease further use of the battery Battery keeps twisting on my back Lay your frames and Ignis out on a flat table Unslide the earpieces from the silicone tubes and relieve any...
Страница 15: ...ue arising from a manufacturing defect for a period of 5 years without charge Batteries and filters are covered for a period of 2 years The liability will not exceed the amount you originally paid for the product The warranty does not cover defects arising from negligence product modification unauthorised repairs accidental damage theft loss or acts of God Warranty present potential risk to human ...
Страница 16: ...yant Dental Old Cow Barn Hilltop Farm Lyne Lane Lyne KT16 0AN Ignis and Bryant Dental are registered trademarks in the United Kingdom and Australia Registered in England Wales No 10396020 Registered in Australia No 634 752 980 www bryant dental Bryant Dental Old Cow Barn Hilltop Farm Lyne Lane Lyne KT16 0AN United Kingdom Possible hazardous optical radiation emitted from this product Do not stare ...