INFORMATION
Basically observe the following 5 safety rules when working on the HV network:
Completely de-energize the system.
Switch off the ignition
Pull out service- / maintenance plug or switch off main battery switch
Remove fuse
Secure system against restarting.
Keep ignition key secured against unauthorized access.
Keep service- / maintenance plug secured against unauthorized access or secure main battery
switch against restarting with lockable cover cap.
Establish zero voltage with suitable voltage tester (observe voltage range!)
Ground and short-circuit system.
Cover or cordon off adjacent live parts.
5.3.3 Safety Instructions for Handling and Operation
DANGER
Danger of electric shock!
In the operating state the ICS is subjected to high voltages and currents. If the device is damaged it is
possible, that live components are exposed. People can come into contact with these components.
It is therefore absolutely imperative to operate the GPM via a separate residual current device (RCD),
which monitors exclusively the function of the GPM.
WARNING
Heating of foreign objects during the inductive transmission of energy!
Risk of fire!
Electrically conducting objects inside the charging magnetic field can heat up considerably, and under
certain circumstances can lead to damage / ignition of other materials. Therefore during the charging
process there must be no objects between CPM and GPM.
WARNING
GPM Magnetic Field!
Danger for living beings and objects!
No person must connect a GPM to the power supply without knowing the safety- and warning signs.
A GPM may only be connected to the power supply, when all persons who are working near the GPM
are aware of the potential dangers.