Technical data
and start-up
BDC546
76
10.4.2 CVI operation
As illustrated below, the CVI software can be used to comfortably specify voltage values, voltage limits and current
limits for the DC/DC converter. Voltages and temperatures measured by the BDC546 as well as error and warning
messages are transmitted to the CVI and displayed.
BRUSA CVI
Please observe that the highside / lowside of the BDC546 has to be pre-charged by means of a pre-
charging resistor as described in chapter
Connect pin 16
EN
with pin 2
AUX
(e.g. actuate ignition key, close switch etc.).
Start the CAN user interface and press the
Go
button in order to enable communication with the device.
Press the
Run
button in order to activate the power stage. Communication with the device is ensured
when the displays
Tx
and
Rx
are flashing.
To enable the main controller to fulfil its function, it is to be guaranteed that no limiting controller is
meshed.
The device can be switched off in every operating mode by pressing the
BDC Activation
button again and
deactivation of pin 16 EN. In case of an emergency, the high voltage can immediately be disconnected by
opening the contactors.
Содержание BDC546
Страница 27: ...27 Technical data and start up BDC546 6 6 Vehicle installation basic principle ...
Страница 82: ...Technical data and start up BDC546 82 16 Attachments 16 1 Cable fitting ...
Страница 83: ...83 Technical data and start up BDC546 ...
Страница 84: ...Technical data and start up BDC546 84 ...
Страница 85: ...85 Technical data and start up BDC546 ...
Страница 86: ...Technical data and start up BDC546 86 16 2 Cable lugs ...
Страница 87: ...87 Technical data and start up BDC546 ...