80
ZTKS0156 / Z31820 / Rev.: 03
Operation
5.2
Energizing
Precondition
•
Cryostat at 4.2 K for at least 12 hours.
•
Helium level at the helium level sensor is above the "minimum level during
energizing" (see Appendix Technical Data of the supplied User Manual).
•
Both PT 100 temperature sensors show the same set value.
•
Cryogenic Refrigerator operating correctly.
5.2.1
Inserting the Current Lead
1.
Prepare the Bruker Power Supply and main power cable.
2.
Remove the plug out of the turret cap of the helium fill-in turret.
3.
Insert the auxiliary shorting plug into the helium fill-in turret.
4.
Remove the shorting plug out of the current lead turret.
5.
Insert the dry current lead into the current lead turret respecting the correct position.
The current lead can only be inserted in one position.
6.
Connect the main power cable and control cables of the Bruker Power Supply with
the current lead.
7.
Connect the short circuit cable to the main power cable until energizing.
8.
Remove the auxiliary shorting plug out of the helium fill-in turret.
9.
Close the helium fill-in turret with the plug of the turret cap.
10. Switch the Bruker Power Supply ON.
Figure 5.1:
Helium Flow System during energizing
1 Current lead
2 Connector
3 One way valve
4 Stop valve
5 Cold Head
6 Quench valves
Содержание RS
Страница 1: ...NMR Spectroscopy Service Manual RS ...
Страница 4: ...4 ZTKS0156 Z31820 Rev 03 ...
Страница 8: ...8 ZTKS0156 Z31820 Rev 03 Table of Contents ...
Страница 10: ...10 ZTKS0156 Z31820 Rev 03 Contact ...
Страница 14: ...14 ZTKS0156 Z31820 Rev 03 Introduction ...
Страница 36: ...36 ZTKS0156 Z31820 Rev 03 Transportation ...
Страница 86: ...86 ZTKS0156 Z31820 Rev 03 Operation ...
Страница 112: ...112 ZTKS0156 Z31820 Rev 03 Troubleshooting ...
Страница 132: ...132 ZTKS0156 Z31820 Rev 03 Disassembling ...
Страница 133: ...133 ZTKS0156 Z31820 Rev 03 A Appendix Warning Signs Figures Tables Glossary Abbreviations Technical Data Index ...
Страница 134: ...134 ZTKS0156 Z31820 Rev 03 Appendix ...
Страница 136: ...136 ZTKS0156 Z31820 Rev 03 Appendix ...
Страница 142: ...142 ZTKS0156 Z31820 Rev 03 Appendix ...
Страница 144: ...144 ZTKS0156 Z31820 Rev 03 Appendix ...
Страница 150: ...150 ZTKS0156 Z31820 Rev 03 Technical Data RS Service This side is intentionally left blank ...
Страница 156: ...156 ZTKS0156 Z31820 Rev 03 ...