BN1100 Revision: 0

Initial Issue: 21/08/2012

ATA 31-10-04

HUMS Accelerometer 

Types 4511-W-006 and 4524-W-001

Abbreviated Component Maintenance Manual

Copyright © 2011, Brüel & Kjær Sound & Vibration Measurement A/S

All rights reserved. No part of this publication may be reproduced or distributed in any form or by any means, without prior 
written consent from Brüel & Kjær Sound & Vibration Measurement A/S, Nærum, Denmark

The document reference is online, please check the correspondence between the online documentation and the printed version.

Содержание 4511-W-006

Страница 1: ...r el Kj r Sound Vibration Measurement A S All rights reserved No part of this publication may be reproduced or distributed in any form or by any means without prior written consent from Br el Kj r Sou...

Страница 2: ...VALIDATION DES OPERATIONS DECRITES DANS CE MANUEL The maintenance operations described in this manual have been verified in the manufacturer s workshop by carrying out exactly dismantling reassembly t...

Страница 3: ...ns 10 2 3 Procedure 10 Appearance 11 Transducer Sensivity Control 11 Electrical Test 12 SECTION 3 Disassembly 13 SECTION 4 Standard and Special Tools 14 4 1 Standard Tools 14 4 2 Special Tools 15 4 2...

Страница 4: ...ronic charge converter enclosed in a hermetic housing The output provides a voltage signal proportional to the acceleration It is powered by a constant current line drive supply on the same wire as th...

Страница 5: ...arge converter enclosed in a hermetic housing The output provides a voltage signal proportional to the acceleration for each axis It is powered by a constant current line drive supply on the same wire...

Страница 6: ...0e 4 Hz ms 2 1 6e 4 Hz ms 2 Linearity 1 Transverse Sensitivity 5 max Temperature Response 10 15 max from 51 C to 150 C referring to sensitivity at 20 C Measurement Axis Perpendicular to the mounting...

Страница 7: ...midity Hermetically sealed Physical Characteristics Dimensions See outline drawings in Fig 2 Weight 35 gram Case Material Stainless steel AISI 316 LS Connector GLENAIR type 8070 1072Z15 3CN Mounting C...

Страница 8: ...Linearity 1 Transverse Sensitivity 5 max Temperature Response 10 max from 45 C to 125 C referring to sensitivity at 20 C Measuring Axes z axis perpendicular to the mounting surface x y z right hand co...

Страница 9: ...Characteristics Dimensions See outline drawings in Fig 4 Weight 50 gram Case Material Stainless steel AISI 316 LS Connector GLENAIR type 8070 1072Z16 4CN Mounting 3 holes in isosceles triangle positio...

Страница 10: ...4 for specification of overall dimensions 2 3 2 Transducer Sensitivity Control The transducer must be calibrated at a temperature around 25 C 5 C This calibration operation will not only test the tra...

Страница 11: ...be Type 4511 W 006 Monoaxial 10 mV accelerometer sensitivity 10 ms2 gain of DMAU 8 Type 4524 W 001 Triaxial 100 mV accelerometer sensitivity 10 ms2 gain of DMAU 8 Note With Type 4524 W 001 Triaxial th...

Страница 12: ...4 W 001 Triaxial use CCLD Power Supply WB 1453 and the cable supplied with it 4 Press the switch in battery position Read the level indicated on the meter the minimum is 23 V 5 Press the switch in bia...

Страница 13: ...The transducer must not be disassembled or attempted to repair If there is a problem contact your Br el Kj r representative who may replace the transducer The document reference is online please chec...

Страница 14: ...Special Tools 4 1 Standard Tools Standard tools are used for removal installation and connecting disconnecting The document reference is online please check the correspondence between the online docum...

Страница 15: ...B 1453 to Type 4524 W 001 not shown Cable WL3428 included with CCLD Power Supply Connect WB 1372 to Type 4511 W 006 WB 3579 For verification of WB1372 cable not shown Reference resistance WB 3579 For...

Страница 16: ...in battery position Read the level indicated on the meter the minimum is 23 V If level is under 23 V change the three 9V batteries inside the box Connect the resistance WB 3579 to the CCLD power suppl...

Страница 17: ...31 10 04 Section 5 Consumables 9 V batteries 6 LR61 for CCLD Power Supply WB 1372 WB 1453 and Calibration Exciter Type 4294 The document reference is online please check the correspondence between th...

Страница 18: ...unit is packed as above it must be stored in clean dry well ventilated premises free from corrosive fumes The temperature should be between 40 to 70 C and relative humidity between 20 and 85 The unit...