Acquiring and displaying measurements
VIBROTEST 60
Page 84 of 168
C102 853.002
© VTEST60E July 2013 4.46ff
5.5
»Process-value« measurement
Measured value:
Process-value
Measured value: Speed
Unit
Unit
START The measurement is started. „STOP„ is displayed to
indicate that the measurement is in progress.
STOP
The measurement is ended. „START„ is displayed to
indicate that the measurement has stopped.
Delete the
entire
Listing memory without confir-
mation request.
DEL 3
Deletes
one data set
from the Listing memory (here
data set No. 3).
AVERAGE On / Off switch for the averaging function.
The measurement process remains active until »STOP« is
pushed.
The display or updating of the measurement is done after each
acquisition step. The last measured value is retained until a
new measurement is started or selection of a new measure-
ment order is made.
The units displayed conform to the configuration »Process-
value Setup« and »System Setup«.
Note:
If the speed and its unit are not displayed, they have not been
activated. The speed measurement can be activated in the
»System Setup«.
Process-values can only be acquired through channel 1 of the
instrument.