7.2.3 Softkeys
According to the instrument status additional softkeys are active
during balancing:
+/-
Allows you to select between „Add weights„ and
„Remove weights„ during unbalance correction.
ADD
In the main menu:
All correction weights attached to the rotor during the
current balancing procedure can be combined into
one single correction weight. VIBROTEST 60 calcu-
lates the resultant weight and its correct location.
In the test weight entry menu:
The selected test weight is added to the existing test
weight.
CR=IR A new balancing procedure is started after the Check
run. The result of the Check run is used for the Initial
unbalance run in the new procedure. The data from
the previous balancing procedure is deleted.
AVERAGE Switching the averaging function On/Off.
RESET Deletes all information from the measuring runs of
the entire balancing procedure.
SELECT The marked measuring run is selected.
START The measurement is started. „STOP„ is displayed
and the channel number flashes to indicate that the
measurement is in progress.
STOP
The measurement is stopped. „START„ is displayed
to indicate that the measurement has stopped.
SUBST The entered test weight replaces the existing test
weight.