BRT Systems LDSBus LA120101A Скачать руководство пользователя страница 1

   

LDSBus Isolated IO Controller Datasheet 

 

Version 1.1 

 

 

Document Reference No.: BRTSYS_000009    Clearance No.: BRTSYS#005 

 

 

Copyright © BRT Systems Pte Ltd 

 

 

1

 

Introduction 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.1

 

Features 

 

 

 

 

 

 

 

 

 

Neither  the  whole  nor  any  part  of  the  information  contained  in,  or  the  product  described  in  this  manual,  may  be  adapted,  or 
Reproduced  in  any  material  or  electronic  form  without  the  prior  written  consent  of  the  copyright  holder.  This  product  and  its 

documentation  are  supplied  on  an  as-is  basis  and  no  warranty  as  to  their  suitability  for  any  particular  purpose  is  either  made  or 
implied. BRT Systems Pte Ltd will not accept any claim for damages howsoever arising as a result of use or failure of this product. 
Your statutory rights are not affected. This product or any variant of it is not intended for use in any medical appliance,  device, or 
System  in  which  the  failure  of  the  product  might  reasonably  be  expected  to  result  in  personal  injury.  This  document  provides 
preliminary information that may be subject to change without notice. No freedom to use patents or other intellectual property rights  
is implied by the publication of this document. BRT Systems Pte Ltd, 178 Paya Lebar Road, #07-03, Singapore 409030. Singapore  
Registered Company Number: 202220043R. 

 

 

LDSBus Isolated IO Controller 

Datasheet  

 

 

The LDSBus Isolated IO Controller offers 2 
isolated channels of digital and analog inputs and 
a variety of associated power source options to 
achieve 3.3V, 5V, 10V, 12V referenced signals 
besides sourcing power from external voltage 
sources. Each channel (input and output) is 
isolated from the others.  
 
Each digital output can switch between 0V and 
3.3V, 5V, 12V or referenced to an external 
voltage source. Each digital input can be between 
0V and 1.8V to 12V. A 5V voltage source is 
provided for common applications that switch 
between 0-5V. 
 
Each analog output can produce a voltage 
between 0-10V, and each analog input supports 
voltage or current controlled input sources 
ranging between 0-10V.  
 
The controller may be used in numerous and 
diverse applications such as simple IO control, or 
0-10V dimmers, weather station, water level 
detector or sensor, etc.  
 

 

2 isolated digital output channels 
 

 

2 isolated digital input channels 

 

 

2 isolated analog output channels 

 

 

2 isolated analog input channels 

 

 

Built-in power supply (3.3V/ 5V/ 10V/ 12V) 
and external power supply option 

 

 

Flexible combination of internal or external 
power supply 

 

 

Supports BRTSYS LDSBus protocol  

 

 

Low power consumption  

 

 

Operating temperature range : 0

o

C to +55

o

 

 

Flush mount and DIN Rail mounting options 
 

 

Supported platforms: LDSBus Host, BRTSYS 
IoTPortal, and PanL Smart Living products. 
Visit 

https://brtsys.com/resources

 

for 

more information

 

 
 

 

 

 

 

 

 

 

Содержание LDSBus LA120101A

Страница 1: ...3R LDSBus Isolated IO Controller Datasheet The LDSBus Isolated IO Controller offers 2 isolated channels of digital and analog inputs and a variety of associated power source options to achieve 3 3V 5V...

Страница 2: ...roller Datasheet Version 1 1 Document Reference No BRTSYS_000009 Clearance No BRTSYS 005 Copyright BRT Systems Pte Ltd 2 2 Part Numbers Part Naming LC060101A LDSBus Isolated IO Controller LA120101A LD...

Страница 3: ...n 6 6 Mounting Options 7 6 1 Flush Mount 7 6 2 DIN Rail Mount 7 7 Terminal Wiring Instructions 8 7 1 Isolated IO Digital INPUT Setup 9 7 2 Isolated IO Digital OUTPUT Setup 10 7 3 Isolated Analog INPUT...

Страница 4: ...e 0V 10V Analog Output resolution 10mV Analog Output Accuracy Typical 3 For 0V 1V Accuracy 10mV typical Digital IO Input Number of Channels 2 Digital Input Voltage 1 8VDC 12VDC refer to external power...

Страница 5: ...005 Copyright BRT Systems Pte Ltd 5 4 Hardware Features Figure 1 LDSBus Isolated IO Controller 2 CH Digital IO Output Output Power Digital IO Power Output Power 2 CH Analog Input 2 CH Analog Output O...

Страница 6: ...Figure 2 illustrates the connection of the LDSBus Isolated IO Controller LDSBus Device to the LDSBus Please visit https brtsys com resources to view the full device application setup and installation...

Страница 7: ...er can be flush mounted directly on a wall or any flat surface using 2 M3 5 16mm thread screws Figure 3 LDSBus Isolated IO Controller Flush Mount 6 2 DIN Rail Mount The LDSBus Isolated IO Controller c...

Страница 8: ...e direction To release the wire turn the handle in an anticlockwise direction Figure 5 Clamping wire with screwdriver in clockwise direction Table 2 provides a list of American Wire Gauges AWGs that c...

Страница 9: ...different configurations IO Digital Input with 5V Application IO Digital Input with External Pull up Use AWG 26 16 The RED wire indicates that it comes from an external IO source Connect to the IN1 o...

Страница 10: ...o 12V The two options for connecting are as follows Digital Output with 5V Application Digital Output with External Source Use AWG 26 16 The BLACK wire connects to on board GND Connect to HV Use AWG 2...

Страница 11: ...source Connect in between VIN1 VIN2 and GND For example Application current source 4mA to 20mA recommend using 450ohm resistor 7 3 Isolated Analog INPUT Setup The 2CH isolated analog input supports e...

Страница 12: ...26 16 The RED wire indicates that it outputs 0V 10V power Connect to VOUT1 or VOUT2 Use AWG 26 16 The BLACK wire indicates that it comes external GND Connect to GND 7 4 Isolated Analog OUTPUT Setup T...

Страница 13: ...l state Device termination is ON Device Status LED Color Flashing Frequency Description Unconfigured device YELLOW LED flashing 1Hz Unconfigured device with factory default address 126 Configured devi...

Страница 14: ...No BRTSYS 005 Copyright BRT Systems Pte Ltd 14 9 Mechanical Dimension Figure 7 LDSBus Isolated IO Controller Dimension Top View Figure 8 LDSBus Isolated IO Controller Dimension Side View Figure 9 LDS...

Страница 15: ...application descriptions suggested BRT Systems devices and other materials is provided for reference only While BRT Systems has taken care to assure it is accurate this information is subject to custo...

Страница 16: ...right BRT Systems Pte Ltd 16 Appendix A References Document References BRTSYS_AN_001_LDSBus_Configuration_Utility_User_Guide Acronyms and Abbreviations Terms Description AC Alternating Current AWG Ame...

Страница 17: ...tatus LED Indicator 13 List of Figures Figure 1 LDSBus Isolated IO Controller 5 Figure 2 LDSBus Isolated IO controller Connection Diagram 6 Figure 3 LDSBus Isolated IO Controller Flush Mount 7 Figure...

Страница 18: ...Ltd 18 Appendix C Revision History Document Title LDSBus Isolated IO Controller Datasheet Document Reference No BRTSYS_000009 Clearance No BRTSYS 005 Product Page https brtsys com ldsbus Document Fee...

Отзывы: