background image

2  

 
 
 

Disclaimer 

 
BIO  RECOGNITION  SYSTEMS  PTY  LTD  LICENCES  THE  SOFTWARE  AND 
DOCUMENTATION  PRODUCT  TO  YOU,  OR  YOUR  COMPANY,  SOLELY  ON  AN 

“AS  IS”  BASIS  AND  SOLELY  IN  ACCORDANCE  WITH  THE  TERMS  AND 
CONDITIONS  OF  THE  ACCOMPANYING  LICENCE  AGREEMENT.  BIO 

RECOGNITION  SYSTEMS  PTY  LTD  MAKES  NO  OTHER  WARRANTIES 
WHATSOEVER  EITHER  EXPRESS  OR  IMPLIED,  REGARDING  THE  SOFTWARE 
OR THE CONTENT OF THE DOCUMENTATION. BIO RECOGNITION SYSTEMS 

PTY  LTD  HEREBY  EXPRESSLY  STATES  AND  YOU  OR  YOUR  COMPANY 
ACKNOWLEDGES  THAT  BIO  RECOGNITION  SYSTEMS  PTY  LTD  DOES  NOT 
MAKE  ANY  WARRANTIES,  INCLUDING,  FOR  EXAMPLE,  WITH  RESPECT  TO 

MERCHANTABILITY, TITLE, OR FITNESS FOR ANY PARTICULAR PURPOSE. 
 
 

Trademarks 

 
BioLock

®

, BioKey

®

 are all registered trademarks of Bio Recognition Systems 

Pty Ltd. 
Microsoft, Windows NT and MS-DOS are registered trademarks of Microsoft 
Corporation. 

Copyright 

 

Copyright © 2005 Bio Recognition Systems Pty Ltd. All rights reserved. 

Reproduction or transmittal of this publication, or portions of the publication, 
is prohibited without the express prior and written consent of the publisher.  
Photocopying and distribution within your organisation is permitted. 

 

Patents & Technology 

 

BioLock

®

 is protected by numerous patents pending and design registrations 

involving its technology. For further information please contact us. 
 

Bio Recognition Systems Pty Ltd 
Unit 11, Building F, 16 Mars Rd,  

Lane Cove NSW, Australia 2066 

AUSTRALIA.

 

Ph: +61 2 9882-8600  Fax: +61 2 9427-2503

 

 
BioLock

®

 Getting Started Manual. 

Version 1.0 
Last Updated: 14 January 2006 

 
 
 
 
 
 
 
 
 

Содержание BioLock

Страница 1: ... io oL Lo oc ck k U Us se er rs s G Gu ui id de e V Ve er rs si io on n 1 1 0 0 Bio Recognition Systems Pty Ltd Unit 11 Building F 16 Mars Rd Lane Cove NSW Australia 2066 Ph 61 2 9882 8600 Fax 61 2 9427 2503 ...

Страница 2: ... Trademarks BioLock BioKey are all registered trademarks of Bio Recognition Systems Pty Ltd Microsoft Windows NT and MS DOS are registered trademarks of Microsoft Corporation Copyright Copyright 2005 Bio Recognition Systems Pty Ltd All rights reserved Reproduction or transmittal of this publication or portions of the publication is prohibited without the express prior and written consent of the pu...

Страница 3: ... Standards Compliance 7 INTRODUCTION 8 HARDWARE INSTALLATION 9 INSTALLING BIOLOCK 9 HARDWARE PROGRAMMING 17 PROGRAMMING BIOLOCK 17 ENTERING ADMIN MODE 17 CONNECTING THE SECURE RELAY BOARD 17 PROGRAMMING THE BIOLOCK RELAY ON TIME 17 TESTING THE RELAY ON TIME DURATION ERROR BOOKMARK NOT DEFINED ADDING USERS 18 DELETING USERS 18 DELETING ALL USERS 18 VERIFYING USERS 18 FACTORY DEFAULT 18 USING BIOLOC...

Страница 4: ......

Страница 5: ...earch Development and BioMetrics Manufacturer based in Sydney NSW Australia Since early 2000 we have been developing and supporting our range of BioMetric Security and Time Management software and hardware solutions This latest product BioLock is a fully embedded finger print device that incorporates all of the features of the more expensive competitive units along with many additional features Co...

Страница 6: ...r by the customer All warranties require that the unit be return back to Bio Recognition Systems Pty Ltd for servicing or repaired through an authorised distributor of Bio Recognition Systems Pty Ltd Finger Sensors or parts that can suffer from wear tear are not covered under this warranty Finger Sensors Power supplies and batteries supplied with Bio Recognition Systems Pty Ltd products are warran...

Страница 7: ...l Biometrics Standards Compliance The product has been tested and has compliance to the following standards BioAPI Compliant ANSI INCITS 358 2002 CBEFF Common Biometric Exchange File Format Compliant NISTIR 6529 2001 ...

Страница 8: ...loyees Incorporating standard 10BaseT communications technology BioLock provides users the ability to run long distances including over the internet removing distance restrictions BioLock can be installed outdoors as it is weather rated to IP65 which means it can handle water jets of low to medium pressure directly without the concerns of damage or ingress into electronic circuitry Being weather r...

Страница 9: ...he supplier who can replace missing components Device LED Indicators Power On Green Led The Green Led indicates power to the device Identify Success Enrolment Yellow Led The Yellow Led indicates a successful scan has taken place also it is used for Enrolment assistance Identity Fail Red Led The Red Led indicates a failed scan has taken place and Is also used for assistance with enrolments Power Re...

Страница 10: ... Terminate all wires used and unused in the screw strips provided to eliminate shorting or failures The 8 Pin White connector on the cable must be passed through the 7mm hole via the rear or back of the metal backplate closest to the wall and in doing the grommet placed on the cable must be tightly inserted into the 7mm hole Leave ample cable hanging out of the hole whilst mounting so that you can...

Страница 11: ...weather proofing Do not remove this lubricant as it is important to the performance of the seal The front housing is designed to come together with the bracket 5 degrees slightly to the left off centre and engage 4 key slots by the heads of the screws protruding from the front housing Once the screws are engaged through the holes the unit may be rotated 5 degrees to the right to the position where...

Страница 12: ...our PC correctly Open up Internet Explorer and type in the address bar http 192 168 0 210 The BioLock Home Page window should appear Select Network to Change the IP and Address Settings of the BioLock Select Sensor Diagnostics to View Images after you have installed software and hardware Select Led Buzzer to Manually Turn on Led s and Sound Buzzer Select Tamper to Ensure that the Tamper Switch is ...

Страница 13: ...located on the CDROM under the Source Files directory These files are BioKey exe Main Executable BioLockAPI dll Communications and Matching DLL Once installed run the Program from the Start Programs BioKey Directory or from the desktop where a shortcut has also been installed the following program window will appear Login password by default on startup is left blank so just press Enter BioKey is d...

Страница 14: ...he wizard will now prompt you to enter the unit details Enter a Unit Name ID and the correct IP address you have assigned You may now enrol a user and template Now you are required to enrol a user template ...

Страница 15: ...15 Once a Unit and User are Configured the Main Form will show ...

Страница 16: ...cure I O Configuration and installation of Secure I O PCB Once you select OK The system is now ready to operate Any person enrolled who touches the BioLock device as long as they have rights then the Secure Relay Board will operate ...

Страница 17: ...the unit Red and Green Leds at the top will flash indicating no users are enrolled Place any Administrators finger on the unit and leave it on the sensor for 5 seconds Quickly remove finger from sensor You are now in Administrator Mode and BioLock is ready to have additional user templates enrolled Connecting the Secure Relay Board The Secure Relay Boards become known to the BioLock units automati...

Страница 18: ...inger If the finger was placed in the same position each time within parameters the GREEN led will come on and the RED will remain off indicating ENROL OK Deleting Users Can only be achieved via the BioKey software Deleting All Users Can only be done from BioKey Software Verifying Users Verifying is a test for a recently enrolled user The user only needs to place their finger on the sensor firmly ...

Страница 19: ...rprint by contacting the sensor surface with the finger placed flat on the sensor as opposed to presenting only the tip of the finger The fingertip alone contains insufficient image data for a high quality fingerprint The ridges in this area are mostly parallel lines with few distinct minutiae from which to construct an identification template It is unlikely that the image management algorithm wil...

Страница 20: ...FRR The FRR is the measurement of the probability that a biometric system will fail to identify an individual who is properly enrolled False Acceptance In biometric systems in general false acceptance errors are the less frequent of the two problems In the case of the BioLock sensor false acceptance is extremely rare and so far always the result of a bad enrollment False Rejection For various reas...

Страница 21: ...at the fingerprint core is kept as centered as possible AT all times the finger must be flat as possible this ensures that the RF signal is correctly directed into the finger to provide a good finger image A good firm press MUST be provided Outer sensor array silver finish approx 3 mm wide Internal Sensor Array Fingerprint Core under nail cuticle Finger ...

Страница 22: ......

Страница 23: ...23 Appendix A G GL LO OS SS SA AR RY Y For future use ...

Страница 24: ......

Страница 25: ...below address fax or email Bio Recognition Systems Pty Ltd Unit 11 Building F 16 Mars Rd Lane Cove NSW AUSTRALIA 2066 Phone 612 9882 8600 Fax 612 9427 2503 Email jonreid brsgrp com BioLock Getting Started Version 1 0 0 Company Address Phone Fax Excellent Good Fair Poor Completeness Readability Format Accuracy Examples Usefulness In what ways could this manual be improved ...

Отзывы: