Effectivity: 914 Series
Rev. 0
BRP-Rotax
Page 3-11
August 01 2019
Step
Procedure
4
TCU-switch to “OFF“ position.
5
After reaching the minimum safe altitude switch on the
TCU.
6
The auxiliary fuel pump should be switched off after
reaching the safety altitude.
3.9) Cruising
Performance
Step
Procedure
1
Set performance as per performance specifications
and respect operating limits as per
Oil temperature
Step
Procedure
1
Avoid operation below normal oil temperature (90 to 110
°C / 194 to 230 °F), as possible formation of condensa-
tion water in the lubrication system badly influences the
oil quality.
To evaporate possibly accumulated condensation water,
at least once a day 100 °C (212 °F) oil temperature must
be reached.
3.10) Engine shut-off
Normally the cooling down of the engine during descending and
taxiing will be sufficient to allow the engine to be shut off as
soon as the aircraft is stopped.
At increased operating temperatures make an engine cooling
run of at least minimum 2 minutes.
3.11) Cold weather operation
Generally, an engine service should be carried out before the
start of the cold season.
Coolant
For selection of coolant and mixing ratio, see
Lubricant
For selection of oil, see table of Lubricants
Cold start
• With throttle closed and choke activated (open throttle ren-
ders starting carb ineffective)
• Be aware, no spark below crankshaft speed of 220 rpm (pro-
peller speed of 90 rpm)
Содержание ROTAX 914 Series
Страница 4: ...Page Table of Content 2 August 01 2019 BRP Rotax Effectivity 914 Series INTENTIONALLY LEFT BLANK...
Страница 6: ...Page INTRO 2 August 01 2019 BRP Rotax Effectivity 914 Series INTENTIONALLY LEFT BLANK...
Страница 66: ...Page 6 2 August 01 2019 BRP Rotax Effectivity 914 Series INTENTIONALLY LEFT BLANK...
Страница 86: ...Page 8 4 August 01 2019 BRP Rotax Effectivity 914 Series INTENTIONALLY LEFT BLANK...
Страница 88: ...9 1 Form Figure 1 Form Page 9 2 August 01 2019 BRP Rotax Effectivity 914 Series Rev 0...
Страница 93: ......
Страница 94: ......
Страница 95: ......