![BRP Evinrude E-TEC Скачать руководство пользователя страница 109](http://html1.mh-extra.com/html/brp/evinrude-e-tec/evinrude-e-tec_manual_2820522109.webp)
109
Electrical and Ignition
Electric Start Tests
6
Starter Voltage Drop Test
Use a digital voltmeter to measure the voltage
drop on each section of the start circuit.
If any voltage reading is greater than 0.5 VDC
check that connections are clean, tight and free of
corrosion. Clean or replace any corroded or dam-
aged cables or connections.
STEP 1:
Connect voltmeter positive (+) lead to
the terminal for the negative (–) battery cable at
powerhead. Connect voltmeter negative (–) lead
to negative (–) battery post.
•
Activate starter motor and observe voltage
reading.
STEP 2:
Connect positive (+) lead to battery posi-
tive (+) terminal. Connect negative (–) lead to
starter solenoid terminal.
•
Activate starter motor and observe voltage
reading.
STEP 3:
First, activate starter motor. Connect
positive (+) lead to starter solenoid terminal. Con-
nect negative (–) lead to opposite starter solenoid
terminal.
•
Observe voltage reading.
STEP 4:
Connect positive (+) lead to starter cable
of solenoid terminal. Connect negative (–) lead to
starter motor terminal.
•
Activate starter motor and observe voltage
reading.
No Load Current Draw Test
Securely fasten starter in a vise or suitable fixture
before proceeding with this check.
Use a battery rated at 500 CCA (60 amp-hr) or
higher that is in good condition and fully charged.
Use an inductive ammeter or connect a 0 to 100
amp ammeter in series with a heavy jumper
between the battery positive (+) terminal and the
starter positive (+) terminal.
Fluke
model 334 or 336,
Snap-On
model MT110
or EETA501, and various other ammeters should
be available through local tool suppliers.
Attach or hold a vibration tachometer, such as a
Frahm
†
Reed
tachometer, to the starter.
Complete the circuit with a heavy jumper between
the battery negative (–) terminal and the starter
frame.
Monitor the starter RPM and current draw.
•
At 10,500 RPM the ammeter should show a
maximum of 30 A.
WARNING
To prevent accidental starting of outboard,
disconnect crankshaft position sensor (CPS).
1.
Negative battery cable
2.
Positive battery cable
3.
Solenoid
4.
Starter cable
008464
–
+
V –
V
–
3
1
2
4
24083
Содержание Evinrude E-TEC
Страница 128: ...Electrical and Ignition Notes 128 Notes Technician s Notes Related Documents Bulletins Instruction Sheets Other...
Страница 230: ...Powerhead Powerhead Views 230 2 Cylinder Port Dressed Powerhead 2 Cylinder Starboard Dressed Powerhead 010510 010508...
Страница 231: ...231 Powerhead Powerhead Views 10 2 Cylinder Port Rope Start Models 2 Cylinder Starboard Rope Start Models 008370 008185...
Страница 232: ...Powerhead Powerhead Views 232 2 Cylinder Front 008160...
Страница 233: ...Powerhead Powerhead Views 233 10 2 Cylinder Rear 010509...
Страница 234: ...Powerhead Powerhead Views 234 2 Cylinder Top 010511...
Страница 235: ...235 Powerhead Powerhead Views 10 2 Cylinder Top Rope Start Models 008186...
Страница 236: ...Powerhead Powerhead Views 236 3 Cylinder Port Hose Routings 3 Cylinder Starboard Hose Routings 006760 006761...
Страница 237: ...237 Powerhead Powerhead Views 10 3 Cylinder Port Dressed Powerhead 3 Cylinder Starboard Dressed Powerhead 010514 010516...
Страница 238: ...Powerhead Powerhead Views 238 3 Cylinder Front 008166...
Страница 239: ...239 Powerhead Powerhead Views 10 3 Cylinder Rear 010515...
Страница 240: ...Powerhead Powerhead Views 240 3 Cylinder Top 010517...
Страница 314: ...314 Trim and Tilt Notes Notes Technician s Notes Related Documents Bulletins Instruction Sheets Other...
Страница 324: ...324 Manual Starter Notes Notes Technician s Notes Related Documents Bulletins Instruction Sheets Other...
Страница 326: ...S 326...
Страница 356: ...I 356 Index Notes Notes Technician s Notes Related Documents Bulletins Instruction Sheets Other...
Страница 364: ...Trouble Check Chart Notes T 364 Notes Technician s Notes Related Documents Bulletins Instruction Sheets Other...