Cooking with Gas
Page 18
Table 1
Burner Type
BTU/HR
Main Burners
13250 x 4
Side Burner
13500 x 1
LP Gas Safety Requirement
For LP gas grills, the LP gas supply tank to be used must be:
(a)
Constructed and marked in accordance with the Specifications for LP Gas Tanks of the U.S.
Department of Transportation (DOT) or the National Standard of Canada, CAN/CSA-B339
Cylinders, Spheres and Tubes for Transportation of Dangerous Goods; and Commission, as
applicable; and
(b)
Provided with a listed Overfill Prevention Device (OPD).
(c)
Provided with a tank connection device compatible with the connection for outdoor cooking
appliances.
The tank should be 12 inches in diameter and 18-1/2 inches tall and be equipped with a Type 1 fitting.
The tank supply system must be arranged for vapor withdrawal.
The tank used must include a collar to protect the cylinder valve.
Do not operate the gas grill indoors or in any enclosed area. If the gas grill is not in use, the gas must
be turned off at the supply tank. If the grill is to be stored indoors, disconnect the gas supply tank and
store the tank in an upright position in a cool, well-ventilated outdoor location away from your grill or
any other heat source.
When checking for gas leaks, do not use an open flame. Use a soapy water solution and apply it to the
pipe joints and fittings with a brush and check for bubbles. Check flexible hoses for cuts and wear that
may affect the safe operation of the grill. Only the factory supplied hose and regulator must be used.
Use only replacement regulator and hose assemblies specified by manufacturer.
Checking Gas Leaks
Before operating your grill, after refueling, check carefully to be certain that all connections are tight
and there are no gas leaks.
1. Make 2-3 ounces of leak solution by mixing liquid dishwashing soap with water.
2. Make certain all control knobs are in the “OFF” position.
3. Brush small amounts of the leak solution on all the fittings, and turn the gas on.
4. If bubbles appear, there is a leak. Proceed to step 5.
5. Turn the gas off, and tighten all connections.
6. Go back to step 1 to retest the fittings.
7. If bubbles continue to appear, turn the gas off. Contact customer service.
Warning: Never use a match or open flame for leak detection. Use of an open flame could result
in a fire, explosion and bodily harm.
IMPORTANT: When connecting or replacing any gas pipe or fittings, all joints must be sealed
with approved leak-proof sealing compound or plumbers tape.