background image

Appendix. Configuration Downlink Command 

Port 

204 

Payload Length 

1~9 bytes 

*Note: Only for unconfirmed downlink. 

 

Appx. 1 Payload 

Bytes 

0~2 

Field 

Cmd 

Config 

 

Appx. 2 Command Description 

Cmd 

Command Description 

Config Length 

0x00 

Get sensor configuration. 

0 byte 

0x00 

Set keep-alive interval, in seconds. 

 

Range: 15~65535 seconds. 

Default: 3600 seconds. 

*Note: little-endian format. 

2 bytes 

0x01 

Set the sensor’s monitor interval, in seconds. 

 

Range: 15~65535 seconds. 

Default: 300 seconds. 

*Note: little-endian format. 

2 bytes 

0x02 

Set delta value to trigger uplink, in lux. 

 

Range: 0~65535 lux. 

Default: 100 lux. 

*Note: little-endian format. 

2 bytes 

 

Example: 
00100E

012C01

026400 

 
00 100E

 Keep-alive interval: 0x0E10 

 3600 sec 

01 2C01

 Monitor interval: 0x012C 

 300 sec 

02 6400

 Trigger delta value: 0x0064 

 100 lux 

 
 

 

 

© 2019 Browan Communications Inc. All rights reserved.

 

13 

 

Содержание TBAM100 Series

Страница 1: ...Ambient Light Sensor Reference Manual TBAM100 915 TBAM100 868 Model Name TBAM100 DOC ver BQW_02_0008 001 ...

Страница 2: ... check code 8 6 1 6 Model Name 8 6 2 PE Bag Back Label Label Barcode 8 7 Important Product Safety Instructions 9 8 Warnings 10 9 Notices 11 10 Cautions 11 11 Regulatory 12 11 1 Federal Communication Commission Interference Statement 12 11 2 Industry Canada statement 13 Appendix Configuration Downlink Command 14 Appx 1 Payload 14 Appx 2 Command Description 14 Appx 3 Response Content 15 Appx 4 Frame...

Страница 3: ...0 C IP Rating IP 40 equivalent 2 3 Radio Frequency 863 870MHz for EU 902 928MHz for North America Tx Power US 19dBm EU 17dBm Rx Sensitivity 135dBm Antenna Gain 2dBi Peak 5dBi Avg 2 4 Certifications and Conformity FCC ID pending IC CE ROHS REACH 2 5 Power Source 3 6V 1 2 AA Li SOCl2 1200mAh battery Maximum Voltage 3 6V Minimum Voltage 3 1V Current TBD 2 6 User Interface LEDs One blue LED 2 7 Additi...

Страница 4: ...efault operation the device will send a join request message after booting for a minute After joining successfully the device will detect the ambient light every 5 minutes When the sensor detects the change of ambient light it will send a status change message Status Change 100 lux delta Keep Alive every 60 minutes 2019 Browan Communications Inc All rights reserved 3 ...

Страница 5: ... 1 status change 0 not status change 1 keep alive 0 not keep alive RFU Battery Battery level Bits 3 0 Bits 7 4 unsigned value ν range 1 14 battery voltage in V 25 ν 10 RFU Temp Temperature as measured by on board NTC Bits 6 0 Bit 7 unsigned value τ range 0 127 temperature in C τ 32 measurement range 32 to 95 C RFU Lux Lux data Bits 23 0 unsigned value 𝛿 Lux 𝛿 100 Note little endian format 2019 Bro...

Страница 6: ...ry or battery pack subjected to extremely low air pressure may also result in an EXPLOSION or leakage of flammable liquid or gas Discard used batteries according to the manufacturer s instructions CAUTION The unit is provided with a battery powered circuit There is a danger of explosion if the battery is incorrectly replaced Replace only with the same or equivalent type recommended by the manufact...

Страница 7: ...ers long 6 1 2 JoinEUI 900MHz 58A0CB0000210000 US AU AS923 BR 800MHz 58A0CB0001500000 EU IN RU Uses a hexadecimal representation resulting in 16 characters 6 1 3 DevEUI 58A0CBFFFFFEFFFF Uses a hexadecimal representation resulting in 16 characters 6 1 4 Model number Non reserved characters except and space with a maximum length of 20 characters 2019 Browan Communications Inc All rights reserved 6 ...

Страница 8: ...el Definition of Back Label and PE Bag Barcode Label GS1 DataMatrix The GS1 Application Identifier 21 indicates that the GS1 Application Identifier data field contains a serial number The GS1 Application Identifier 92 assigned to the company s internal information is DevEUI Caution For more information please refer to chapter 5 2 and chapter 10 2019 Browan Communications Inc All rights reserved 7 ...

Страница 9: ...ld Do not allow children or pets to play with products Observe proper precautions when handling batteries Batteries may leak or explode if improperly handled Observe the following precautions to avoid a sensor explosion or fire Do not drop disassemble open crush bend deform puncture shred microwave incinerate or paint the sensors Hub or other hardware Do not insert foreign objects into any opening...

Страница 10: ...ery leaking do not allow the liquid to come in contact with the skin or eyes If contact has been made wash the affected area with copious amounts of water and seek medical advice Do not use any charger other than that specifically provided for use with the equipment Observe the plus and minus marks on the battery and equipment and ensure correct use Do not use any which is not designed for use wit...

Страница 11: ...oducts Do not use detergent or abrasive materials to clean the Tabs products as this may damage the sensors 10 Cautions CAUTION Disposal of a battery or battery pack into a fire or a hot oven or mechanically crushing or cutting of a battery or battery pack can result in an EXPLOSION Leaving a battery or battery pack in an extremely high temperature surrounding environment that can result in an EXP...

Страница 12: ... radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is ...

Страница 13: ...ant provoquer un fonctionnement indésirable de l appareil The product complies with the Canada portable RF exposure limit set forth for an uncontrolled environment and are safe for intended operation as described in this manual The further RF exposure reduction can be achieved if the product can be kept as far as possible from the user body or set the device to lower output power if such a functio...

Страница 14: ...econds Default 3600 seconds Note little endian format 2 bytes 0x01 Set the sensor s monitor interval in seconds Range 15 65535 seconds Default 300 seconds Note little endian format 2 bytes 0x02 Set delta value to trigger uplink in lux Range 0 65535 lux Default 100 lux Note little endian format 2 bytes Example 00100E 012C01 026400 00 100E Keep alive interval 0x0E10 3600 sec 01 2C01 Monitor interval...

Страница 15: ...Trigger delta value 0x0064 100 lux Appx 4 Frame Count 0 Content Payload Length 17 bytes Payload Content Frame count 0 content Ex 01 06000000 00180000 7ff1f102 e2d4f6ee 01 command ID 06000000 bootloader version 0x00000006 little endian format 00180000 HW ID 0x00001800 little endian format 7ff1f102 FW CRC 0x02f1f17f little endian format e2d4f6ee PubKey ID 0xeef6d4e2 little endian format 2019 Browan ...

Отзывы: