MCe 9.0-21

PORTABLE AIR CONDITIONER.

PRODUCT MANUAL.

MCe 9.0-21

SHEET 1 OF 13

Содержание MCe 9.0-21

Страница 1: ...MCe 9 0 21 PORTABLE AIR CONDITIONER PRODUCT MANUAL MCe 9 0 21 SHEET 1 OF 13 ...

Страница 2: ...rtant information P3 4 Technical specification P4 Set up and operation P5 6 Setting the digital thermostat P7 Control diagrams P8 Maintenance P9 10 Spare parts P11 12 Wiring diagrams P13 TABLE OF CONTENTS SHEET 2 OF 13 ...

Страница 3: ...op of the appliance An air gap of at least 300mm should be allowed at the front and rear of the unit to ensure a clear airflow Do not disconnect the appliance from the supply under load For internal use only Do not use out of doors Warning Exhaust fan liable to start without notice Extension cables should be correctly rated for the load fully unwound and never run through water or over sharp edges...

Страница 4: ...size for safe operation WARNING Do not use means to accelerate the defrosting process or to clean other than those recommended by the manufacturer The appliance shall be stored in a room without continuously operating ignition sources for example open flames an operating gas appliance or an operating electric heater Do not pierce or burn Be aware that refrigerants may not contain an odour SHEET 4 ...

Страница 5: ...aust spigot supplied loose The rear exhaust spigot must be fitted before use Tools required No2 PZ screwdriver 1 Remove the 4 x M5 fixings with star washers at the rear of the machine 2 Use these fixings to secure the exhaust spigot in place Pinch tight Ensure the star washers are refitted Exhaust spigot fitted SHEET 5 OF 13 ...

Страница 6: ...compressor will not start if the fan switch is not in the on position or the ambient temperature is below 15 C The compressor is fitted with a start delay timer and will not run for 3 minutes from activation of the cooling switch This device is designed to protect the compressor from repeated start stop cycles Set the digital thermostat to the desired temperature This is the set point During norma...

Страница 7: ...oom temperature How to see the set point Defrost key Not used Set key Up down keys Power key Not used The appliance comes factory set at 15 C Push the SET key for more than 2 seconds to change the set point value The value of the set point will be displayed and the C LED starts blinking To change the set point value push the up or down arrows within 10 seconds The minimum set point is 15 C To memo...

Страница 8: ...tank Locking castors Discharge hoses Exhaust spigot Digital controller Fans on rocker switch Tank full lamp Cooling on rocker switch Variable fan speed controller Control panel Operation and controls SHEET 8 OF 13 ...

Страница 9: ... available to hand Either Co2 or dry powder g All possible ignition sources should be kept sufficiently far away from the work area h Adequate ventilation shall be provided when breaking into the refrigeration system The ventilation should safely disperse any released refrigerant to the external atmosphere i When replacing electrical components only spare parts specified by the manufacturer shall ...

Страница 10: ...nk drain mechanism is operating correctly and the drain hose is present and in good condition 3 Regularly inspect the mains cable and plug for signs of damage or wear Do not operate the machine with a damaged mains cable 4 Check that the castors are running freely and that the breaking mechanisms are working correctly Troubleshooting guide SHOULD YOU CONTINUE TO EXPERIENCE PROBLEMS PLEASE CONTACT ...

Страница 11: ...33 34 27 29 28 31 32 30 25 1 2 3 4 5 7 8 9 10 11 12 13 14 15 16 18 20 21 22 23 24 41 26 Exploded view 6 17 19 35 SHEET 11 OF 13 ...

Страница 12: ...Spare Parts SHEET 12 OF 13 ...

Страница 13: ...MCe 9 0 21 Wiring diagram SHEET 13 OF 13 ...