72
ZM-850A, 851A
—
21
—
55
57
Caution
Problem
Possible cause
Page
10. Broken needles
•
Is the material being pushed or pulled with excessive force dur-
ing sewing?
•
Is the needle properly installed?
If it is incorrect, install the needle correctly.
•
Is the needle bent, is the needle tip broken, or is the needle
hole blocked?
Replace the needle.
•
Is the needle and rotary hook timing incorrect?
Adjust the height of the needle bar.
Adjust the clearance between the needle and the rotary hook.
•
It is extremely dangerous to leave any pieces of broken
needle sticking in the material. If the needle breaks, search
for all pieces until the whole of the needle is found again.
•
Furthermore, we recommend that through steps be taken
to account for such needles to comply with product liability
regulations.