[ 14 ]Removing the Cover Open Sensor and Movable Sensor PCB ASSY
(1) Remove the taptite bind B M2.6X6 screw to remove the SW hold plate and the
cover open sensor from the upper cover.
(2) Slide the movable sensor PCB ASSY in the direction of the arrow, and remove it
by aligning its four tabs to four notches on the upper cover.
Figure 3.4-18
Tabs
Movable sensor PCB ASSY
Movable sensor
PCB ASSY
Cover open sensor
SW hold plate
Tabs
Taptite bind B M2.6X6
Upper cover
Upper cover