![Brother QL-1050 Скачать руководство пользователя страница 65](http://html.mh-extra.com/html/brother/ql-1050/ql-1050_service-manual_55187065.webp)
III-
40
[ 5 ] Installing the Upper Cover ASSY
(1) Insert the tape sensor PCB ASSY into the insert guide.
Note 1: Insert the tape sensor PCB ASSY until it hits the rib of the insert guide.
Note 2: Confirm that you can see the tape sensor PCB ASSY from the hole of the insert
guide.
Note 3: Fold the flat cable after assembling the tape sensor PCB ASSY.
Important: When replacing the tape sensor PCB ASSY or insert guide, implement each
operation described in “APPENDIX 1. MAINTENANCE SOFTWARE
OPERATION”.
Fig. 3.2-23 Installing the Upper Cover ASSY (1)
(2) Assemble the insert guide onto the upper cover ASSY with the one screw.
Fig. 3.2-24 Installing the Upper Cover ASSY (2)
Tape sensor PCB ASSY
Insert guide
Flat cable
Insert guide
Upper cover ASSY
Tape sensor PCB ASSY
Insert guide
Screw
Rib
Put the tape sensor
through the rib.
Tape sensor
PCB ASSY