Confidential
2-35
Error Code 48
Head flat cable detected to be not correctly inserted.
Error Code 49
Head voltage does not raise.
User Check
- They may occur due to lower surrounding temperature. Use in warmer surrounding
temperature.
Unable to Print 48
LCD
Step
Cause
Solution
1
Head flat cable connection
failure
Reconnect the head flat cable.
2
Carriage flat cable connection
failure
Reconnect the carriage flat cable.
3
Carriage PCB defective
Replace the carriage PCB ASSY.
4
Head defective
Replace the head/carriage unit.
5
Main PCB defective
Replace the main PCB ASSY.
Unable to Print 49
LCD
Step
Cause
Solution
1
Head flat cable connection
failure
Reconnect the head flat cable.
2
Carriage flat cable connection
failure
Reconnect the carriage flat cable.
3
Carriage PCB defective
Replace the carriage PCB ASSY.
4
Head defective
Replace the head/carriage unit.
5
Power supply PCB defective
Replace the power supply PCB ASSY.
6
Main PCB defective
Replace the main PCB ASSY.
Содержание MFC-J6920DW
Страница 123: ...3 3 Confidential 2 PACKING ...
Страница 146: ...3 26 Confidential 3 Set the protective part Protective part ...
Страница 279: ...5 8 Confidential head_calib1_BHM13 prn data Fit this mark on the left rear of the document cover ...
Страница 280: ...5 9 Confidential head_calib2_BHM13 prn data Fit this mark on the left rear of the document cover ...
Страница 308: ...5 37 Confidential pfadj2 Pattern ...
Страница 315: ...5 44 Confidential Margin Check Pattern ...
Страница 362: ...App 3 8 Confidential When the following screen appears click Close to close the screen ...