Error code 6A00
The center thermistor of the fuser unit has not reached the specified temperature within the specified time.
Error code 6B00
The center thermistor of the fuser unit has not reached the specified temperature within the specified time.
Error code 6C00
The center thermistor of the fuser unit detected a temperature higher than the specified value.
Error code 6D00
After the heat unit was heated normally, the center thermistor of the fuser unit detected a
temperature lower than the specified value.
Error code 6E00
The center thermistor of the fuser unit detected that the heat unit was not heated.
Error code 6F00
The center thermistor or the side thermistor of the fuser unit detected a temperature error.
Fuser Error / Print Unable 6A
Turn the power off and then back on again.
Fuser Error / Print Unable 6B
Turn the power off and then back on again.
Fuser Error / Print Unable 6C
Turn the power off and then back on again.
Fuser Error / Print Unable 6D
Turn the power off and then back on again.
Fuser Error / Print Unable 6E
Turn the power off and then back on again.
Fuser Error / Print Unable 6F
Turn the power off and then back on again.
<User Check>
• Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.
Step
Cause
Remedy
1
Connection failure of the center
or side thermistor harness of
the fuser unit
Check the connection of the center or side
thermistor harness of the fuser unit, and
reconnect it if necessary.
2
Connection failure of the heater
harness of the fuser unit
Check the connection of the heater harness of
the fuser unit, and reconnect it if necessary.
3
Connection failure of the eject
sensor PCB harness
Check the connection of the eject sensor PCB
harness, and reconnect it if necessary.
4
Connection failure of the low-
voltage power supply PCB harness
Check the connection of the low-voltage power
supply PCB harness, and reconnect it if necessary.
5
Eject sensor PCB failure
Refer to
"1.3.10 Check sensor operation
(function code: 32)" in Chapter 5
to check the
sensor operation. If the sensor operation is
faulty, replace the eject sensor PCB ASSY.
6
Fuser unit failure
Replace the fuser unit.
7
Low-voltage power supply PCB
failure
Replace the low-voltage power supply PCB
ASSY.
8
Main PCB failure
Replace the main PCB ASSY.
Содержание MFC-8510DN
Страница 27: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Страница 43: ...Confidential CHAPTER 2 TROUBLESHOOTING ...
Страница 53: ...2 8 Confidential 2 2 2 Scanning Legal model Fig 2 5 A4 model Fig 2 6 Document feed path Document feed path ...
Страница 143: ...Confidential CHAPTER 3 DISASSEMBLY REASSEMBLY ...
Страница 154: ...3 8 Confidential Develop joint gear 37 Fig 3 4 Document scanner unit A4 model Fig 3 5 Legal model Fig 3 6 ...
Страница 155: ...3 9 Confidential Hinge ASSY L Fig 3 7 Hinge R Legal model only Fig 3 8 ...
Страница 165: ...3 19 Confidential 11 Main frame R Harness colors may be changed for any reason NCU earth harness BR Guides ...
Страница 201: ...3 55 Confidential 13 Remove the LCD and touch panel ASSY from the panel cover Fig 3 70 Touch panel ASSY Panel cover LCD ...
Страница 277: ...Confidential CHAPTER 4 ADJUSTING AND UPDATING SETTINGS AS REQUIRED AFTER PARTS REPLACEMENT ...
Страница 293: ...Confidential CHAPTER 5 SERVICE FUNCTIONS ...
Страница 300: ...5 5 Confidential Fig 5 1 ...
Страница 325: ...5 30 Confidential Fig 5 14 ...
Страница 327: ...5 32 Confidential Fig 5 15 ...
Страница 346: ...Confidential CHAPTER 6 WIRING DIAGRAM ...
Страница 348: ...6 1 Confidential 1 WIRING DIAGRAM Wiring diagram ...
Страница 349: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Страница 368: ...Confidential APPENDIX 1 SERIAL NUMBERING SYSTEM ...
Страница 372: ...Confidential APPENDIX 3 INSTALLING MAINTENANCE DRIVER ...