4.7.5 Cannot register
4.7.6 Counter does not reset even the consumable part has been replaced
4.7.7 Installation using USB flash memory is not operable
<User Check>
- Check that the number of items registered has not been exceeded.
- Check the network connection.
- Check the relevant section in the Network Setting Guide.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
<User Check>
- Refer to the User's Guide to reset the pick up roller and reverse roller counters.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
Step
Cause
Remedy
1
"FIRM" folder cannot be found
under the USB flash memory
Create the "FIRM" folder under the USB
flash memory.
2
"_@$UPD$OP0.8080" file for
automatic firmware update cannot
be found under the USB flash
memory
Save the "_@$UPD$OP0.8080" file for
automatic firmware update under the USB
flash memory.
3
Firmware (djf file) cannot be found
in the "FIRM" folder
Save the firmware (djf file) in the "FIRM"
folder.
4
There is an unnecessary file in the
"FIRM" folder
Delete the unnecessary file from the "FIRM"
folder.
5
Firmware (djf file) in the "FIRM"
folder is not for the specific model
Save the firmware (djf file) for the specific
model in the "FIRM" folder.
6
Cannot run "FirmUPDATE" as a
program is already running
Install the firmware after the currently
running function is finished.
7
USB flash memory is broken
Replace it with the other USB flash memory
to install the firmware.
Содержание ImageCenter ADS-2800W
Страница 24: ...2 4 Confidential 2 2 Paper Feeding Fig 2 2 Feed path Front side Back side ...
Страница 50: ...3 2 Confidential 2 PACKING ...
Страница 53: ...3 5 Confidential 5 LUBRICATION There are no applicable parts for lubrication ...
Страница 54: ...3 6 Confidential 6 OVERVIEW OF GEARS There are no gears to be disassembled ...