5-38
Confidential
1.4.15 Changing return value of USB No./
Adjusting of left-end print start position on second side in 2-sided printing
(Function code 45)
Changing return value of USB No.
<Function>
When the OS of the computer is Windows Vista
®
, and the computer is connected to a device
through USB 2.0 full speed, the OS might fail to get the serial No. of the USB device
depending on the computer and USB device. When the OS fails to get the serial No., the
return value may continue to increase every time the device is connected to the computer.
To avoid this problem, you can fix the return value of the USB No. to "0" by setting "USBNo. =
ON". (This is the same function as
"2.4 Changing Return Value of USB No." in this chapter
"*" is displayed at the end of the currently specified function in the LCD display.
<Operating procedure>
(1) Press the
4
and
5
buttons in this order in the initial state of the maintenance mode.
"USBNo." is displayed on the LCD.
(2) Press the
OK
button. "USBNo.=ON" is displayed on the LCD.
(3) When you press the
or
button to fix the return value of serial number to "0" or not to
fix it to "0", display "USBNo. = ON" or "USBNo. = OFF", respectively.
(4) Press the
OK
button. "Accepted" is displayed on the LCD, and the product returns to the
initial state of the maintenance mode.
(5) Turn the power switch of the machine OFF.
Adjusting left-end print start position on second side in 2-sided printing
<Function>
This function is to adjust the left-end print start position on the second side in the left and right
direction if it is displaced in 2-sided printing.
The adjustable range is -100 to 750 (unit: 300 dpi) (The minus direction means the left direction.)
<Operating procedure>
(1) Press the
4
and
5
buttons in this order in the initial state of the maintenance mode.
"USBNo." is displayed on the LCD.
(2) Press the
or
button to display "DX.XAdjust" on the LCD.
(3) Press the
OK
button. "DX.XAdjust=**" is displayed on the LCD.
(** represents the currently set value.)
(4) To move the print start position to the left, press the
button and decrease the value.
To move the print start position to the right, press the
button and increase the value.
(5) Press the
OK
button. "Accepted" is displayed on the LCD, and the product returns to the
initial state of the maintenance mode.
LCD
Description
USBNo. =ON
Returns the serial No. of the device. (default)
USBNo. =OFF
Returns "0".
Note:
This function is enabled when the power of the machine is turned OFF and ON.
Содержание HL-S7000DN Series
Страница 156: ...2 128 Confidential 8 Close the Top cover and the MP cover ASSY Fig 2 16 Top cover MP cover ASSY ...
Страница 176: ...3 8 Confidential 5 LUBRICATION There are no applicable parts ...
Страница 181: ...3 13 Confidential 3 Ink Refill Unit Ink refill unit Hook Clamp Hook Hook Hook Engine PCB ASSY ...
Страница 185: ...3 17 Confidential 8 Buffer Tank ASSY Clamp Clamp Buffer tank ASSY Buffer tank ASSY CN3 CN4 Maintenance drive PCB ASSY ...
Страница 245: ...3 77 Confidential 8 Close the Top cover Fig 3 80 Top cover Front ...
Страница 356: ...4 13 Confidential Print start position adjustment pattern Fig 4 6 A ...
Страница 358: ...4 15 Confidential All patterns Fig 4 7 B C B C A ...
Страница 359: ...4 16 Confidential Fig 4 8 D E D E ...
Страница 360: ...4 17 Confidential Fig 4 9 G F B C B C ...
Страница 417: ...5 29 Confidential Waste ink tray Fig 5 17 Waste ink box full sensor Waste ink box leak sensor Waste ink box sensor ...
Страница 421: ...5 33 Confidential ENGN ALL Fig 5 20 ...
Страница 422: ...5 34 Confidential MAIN TOP Fig 5 21 ...
Страница 423: ...5 35 Confidential MAIN BTM Fig 5 22 ...
Страница 424: ...5 36 Confidential MAIN ALL Fig 5 23 ...