2-74
Confidential
■
Error code 6801
Internal thermistor detected temperature at or above the given temperature.
<User Check>
- Wait until the temperature of the machine falls below the given temperature before turning
ON the power.
- Decrease the room temperature.
■
Error code 6802
Ink head thermistor detected temperature at or above the given temperature.
<User Check>
- Wait until the temperature of the machine falls below the given temperature before turning
ON the power.
- Decrease the room temperature.
Cooling Down
Wait for a while.
Step
Cause
Remedy
1
Engine PCB failure
Replace the engine PCB ASSY.
Cooling Down
Wait for a while.
Step
Cause
Remedy
1
Head thermistor failure
Replace the ink head or pre-coat head.
2
Engine PCB failure
Replace the engine PCB ASSY.
Содержание HL-S7000DN Series
Страница 156: ...2 128 Confidential 8 Close the Top cover and the MP cover ASSY Fig 2 16 Top cover MP cover ASSY ...
Страница 176: ...3 8 Confidential 5 LUBRICATION There are no applicable parts ...
Страница 181: ...3 13 Confidential 3 Ink Refill Unit Ink refill unit Hook Clamp Hook Hook Hook Engine PCB ASSY ...
Страница 185: ...3 17 Confidential 8 Buffer Tank ASSY Clamp Clamp Buffer tank ASSY Buffer tank ASSY CN3 CN4 Maintenance drive PCB ASSY ...
Страница 245: ...3 77 Confidential 8 Close the Top cover Fig 3 80 Top cover Front ...
Страница 356: ...4 13 Confidential Print start position adjustment pattern Fig 4 6 A ...
Страница 358: ...4 15 Confidential All patterns Fig 4 7 B C B C A ...
Страница 359: ...4 16 Confidential Fig 4 8 D E D E ...
Страница 360: ...4 17 Confidential Fig 4 9 G F B C B C ...
Страница 417: ...5 29 Confidential Waste ink tray Fig 5 17 Waste ink box full sensor Waste ink box leak sensor Waste ink box sensor ...
Страница 421: ...5 33 Confidential ENGN ALL Fig 5 20 ...
Страница 422: ...5 34 Confidential MAIN TOP Fig 5 21 ...
Страница 423: ...5 35 Confidential MAIN BTM Fig 5 22 ...
Страница 424: ...5 36 Confidential MAIN ALL Fig 5 23 ...